The accuracy of Finapres noninvasive mean arterial pressure measurements in anesthetized patients.

N M Gibbs1, D R Larach, J A Derr.   

Abstract

The Finapres (FIN) is a new noninvasive blood pressure monitor that provides continuous arterial waveform display with the use of a finger cuff. The authors assessed the accuracy of FIN mean arterial pressure (MAP) measurements relative to simultaneous direct radial arterial pressures in 20 patients undergoing general anesthesia for major elective surgery. Data were collected digitally with the use of RS-232 communications over a total of 16.2 h. The data were processed into 6012 interference-free time samples, each spanning 6 s. The authors determined the difference between FIN and direct MAPs during each time sample. The authors calculated not only the bias of FIN measurements, but also the frequency, magnitude, and duration of discrepancies between simultaneous FIN and direct MAPs. The overall bias of the FIN MAP was -0.5 +/- 1.0 mmHg, which was not significantly different from zero. However, 32.3 +/- 6.2% of all MAP comparisons differed by greater than +/- 10 mmHg, and 5.0 +/- 1.1% differed by greater than +/- 20 mmHg. Moreover, there was an average of one episode every 2 patient-hours when the FIN MAP differed by greater than +/- 20 mmHg for more than 1 min. Although the MAP measured by FIN accurately reflected direct MAPs most of the time, there were occasional discrepancies of different magnitude such that clinical usefulness may be limited in patients in whom continuous accurate blood pressure measurements are essential.

Entities:  

Mesh:

Year:  1991        PMID: 2008944     DOI: 10.1097/00000542-199104000-00004

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  12 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  The mean prehospital machine; accurate prehospital non-invasive blood pressure measurement in the critically ill patient.

Authors:  Sandy Muecke; Andrew Bersten; John Plummer
Journal:  J Clin Monit Comput       Date:  2010-06-08       Impact factor: 2.502

3.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

4.  An evaluation of the N-CAT, a new arterial tonometer.

Authors:  N R Searle; J Gauthier; P Sahab
Journal:  Can J Anaesth       Date:  1995-06       Impact factor: 5.063

5.  Assessment of the arterial tonometer (N-CAT) for the continuous blood pressure measurement in rapid atrial fibrillation.

Authors:  N R Searle; J Perrault; H Ste-Marie; C Dupont
Journal:  Can J Anaesth       Date:  1993-04       Impact factor: 5.063

6.  Validation of arterial blood pressures observed from the patient monitor; a tool for prehospital research.

Authors:  Sandy Muecke; Andrew Bersten; John Plummer
Journal:  J Clin Monit Comput       Date:  2009-12-18       Impact factor: 2.502

7.  Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

Authors:  Ali A Saherwala; Sonja E Stutzman; Mohamed Osman; Junaid Kalia; Stephen A Figueroa; DaiWai M Olson; Venkatesh Aiyagari
Journal:  Neurocrit Care       Date:  2018-06       Impact factor: 3.210

8.  Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the Finapres: a spectral analysis approach.

Authors:  V Novak; P Novak; R Schondorf
Journal:  J Clin Monit       Date:  1994-03

9.  The mean machine; accurate non-invasive blood pressure measurement in the critically ill patient.

Authors:  Sandy Muecke; Andrew Bersten; John Plummer
Journal:  J Clin Monit Comput       Date:  2009-08-12       Impact factor: 2.502

10.  Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system.

Authors:  Matthieu Biais; Laurent Stecken; Aurélie Martin; Stéphanie Roullet; Alice Quinart; François Sztark
Journal:  J Clin Monit Comput       Date:  2016-06-16       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.