An evaluation of the N-CAT, a new arterial tonometer.

N R Searle1, J Gauthier, P Sahab.   

Abstract

The N-CAT is a newly developed arterial tonometer (TBP) monitor able to determine systolic, diastolic and mean blood pressures continuously and noninvasively. The aim of this study was to evaluate the accuracy and reliability of the TBP compared with directly measured invasive blood pressure (IBP) in 14 patients before and after elective coronary artery bypass surgery. Although the TBP was able to track changes in systemic pressure, before and after CPB, bias and precision for TBP monitoring did not meet the standard criteria for equivalency for noninvasive blood pressure to invasive blood pressure. We were unable to monitor TBP in two patients. Approximately 40% of all before and after CPB mean TBP pressure values differed from mean IBP by more than 10 mmHg. Moreover, there were discrepancies of sufficient magnitude and duration that limits the clinical usefulness of the N-CAT. Potential users should not rely exclusively on TBP values when making clinical decisions. Technological improvement is needed before its clinical use is recommended.

Entities:  

Mesh:

Year:  1995        PMID: 7628035     DOI: 10.1007/BF03011693

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  12 in total

1.  Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia.

Authors:  O Kemmotsu; M Ueda; H Otsuka; T Yamamura; D C Winter; J S Eckerle
Journal:  Anesthesiology       Date:  1991-08       Impact factor: 7.892

2.  Accuracy and dynamic response of disposable pressure transducer-tubing systems.

Authors:  P Hunziker
Journal:  Can J Anaesth       Date:  1987-07       Impact factor: 5.063

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Assessment of the arterial tonometer (N-CAT) for the continuous blood pressure measurement in rapid atrial fibrillation.

Authors:  N R Searle; J Perrault; H Ste-Marie; C Dupont
Journal:  Can J Anaesth       Date:  1993-04       Impact factor: 5.063

5.  Comparison of arterial tonometry with radial artery catheter measurements of blood pressure in anesthetized patients.

Authors:  L C Siegel; J G Brock-Utne; J B Brodsky
Journal:  Anesthesiology       Date:  1994-09       Impact factor: 7.892

6.  Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass?

Authors:  D H Stern; J I Gerson; F B Allen; F B Parker
Journal:  Anesthesiology       Date:  1985-05       Impact factor: 7.892

7.  Arterial tonometry: review and analysis.

Authors:  G M Drzewiecki; J Melbin; A Noordergraaf
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

Review 8.  Comparison of direct and indirect measuring arterial blood pressure.

Authors:  J M Bruner; L J Krenis; J M Kunsman; A P Sherman
Journal:  Med Instrum       Date:  1981 Jan-Feb

9.  The accuracy of Finapres noninvasive mean arterial pressure measurements in anesthetized patients.

Authors:  N M Gibbs; D R Larach; J A Derr
Journal:  Anesthesiology       Date:  1991-04       Impact factor: 7.892

10.  Blood pressure measurement by arterial tonometry in controlled hypotension.

Authors:  O Kemmotsu; M Ueda; H Otsuka; T Yamamura; A Okamura; T Ishikawa; D C Winter; J S Eckerle
Journal:  Anesth Analg       Date:  1991-07       Impact factor: 5.108

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.