Literature DB >> 8451940

Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases.

E Sim1.   

Abstract

Postoperative CT examinations of an unselected group of 45 patients with fractures of the thoracolumbar and lumbar spine including 1 patient with traumatically activated spondylolisthesis were analyzed for the location of the 200 screws, the angles of insertion, and the screw vs pedicle diameters. In all cases transpedicular systems had been used for fixation, i.e., the AO-Fixateur Interne in 28 patients, a combination of Teinturier plates and USI screws in 11 patients, and the VSP system in 7 patients. Using a standardized surgical technique and image intensification in 2 planes throughout, 92 percent of all pedicles were instrumented with acceptable deviations from the anatomic axes. Mismatches between the pedicle and the screw diameters were found in 3 instances, and 2 screws were placed in the transverse processes only. Canal encroachment in 13 patients did not impede neural structures. Slight perforation of the anterior cortex of the vertebral body was recorded in 3 percent of cases, but did not cause any complications.

Entities:  

Mesh:

Year:  1993        PMID: 8451940     DOI: 10.3109/17453679308994522

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  Effect of brightness in the evaluation of lumbar pedicular screws position: clinical study.

Authors:  L M Romero-Muñoz; M Alfonso; C Villas; J L Zubieta
Journal:  Musculoskelet Surg       Date:  2013-04-05

Review 3.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

4.  Accuracy Assessment of Freehand Pedicular Screw Placement.

Authors:  Afshin Ahmadzadeh Heshmati; Shahab Ilka
Journal:  Arch Bone Jt Surg       Date:  2020-07

5.  [Navigation of tumors and metastases in the area of the thoraco-lumbar spine].

Authors:  F Gebhard; L Kinzl; E Hartwig; M Arand
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

6.  A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine.

Authors:  Yong Hu; Zhen-Shan Yuan; William Ryan Spiker; Wei-Xin Dong; Xiao-Yang Sun; Jian-Bing Yuan; Jiao Zhang; Bingke Zhu
Journal:  Eur Spine J       Date:  2016-03-28       Impact factor: 3.134

7.  Cost-effectiveness of image-guided spine surgery.

Authors:  Robert Green Watkins; Akash Gupta; Robert Green Watkins
Journal:  Open Orthop J       Date:  2010-08-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.