Literature DB >> 32884973

Accuracy Assessment of Freehand Pedicular Screw Placement.

Afshin Ahmadzadeh Heshmati1, Shahab Ilka1.   

Abstract

BACKGROUND: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion without the use of fluoroscopy.
METHODS: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion. The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvic fractures and were managed with triangular osteosynthesis fixation. However, those with scoliosis deformity were excluded from the study. A total of 760 pedicular screws were inserted in C7 to S1 vertebrae without using fluoroscopy. The locations of the screws were assessed by means of computed tomography scan after the surgery. The data were analyzed in SPSS software (version 22) using the Chi-square test.
RESULTS: Out of 387 thoracic screws and 373 lumbar screws, 65 (16.8%) and 34 (9.1%) screws perforated the pedicle wall or vertebral body, respectively. The most frequent locations of perforation in the thoracic and lumbar spine were the anterior cortex of the vertebral body and medial wall of the pedicle, respectively. Except for the perforation of the anterior vertebral body (P=0.0001), there was no difference between the left and right sides or between thoracic and lumbar sites in terms of the preformation of the screw. No complication was observed due to screw perforation.
CONCLUSION: Our findings revealed the unnecessity of using fluoroscopy in spine surgeries for the insertion of pediculate screws. In this regard, the use of fluoroscopy for the placement of pedicular screw resulted in similar accuracy and complications, as compared to the free hand procedure. COPYRIGHT 2020 © BY THE ARCHIVES OF BONE AND JOINT SURGERY.

Entities:  

Keywords:  Fluoroscopy; Lumbar; Pedicular screw; Spine fixation; Thoracic

Year:  2020        PMID: 32884973      PMCID: PMC7443073          DOI: 10.22038/abjs.2018.31503.1819

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  16 in total

1.  A prospective study on the use of intraoperative computed tomography (iCT) for image-guided placement of thoracic pedicle screws.

Authors:  Shree Kumar Dinesh; Rajendra Tiruchelvarayan; Ivan Ng
Journal:  Br J Neurosurg       Date:  2012-06-15       Impact factor: 1.596

2.  Outcome-based classification for assessment of thoracic pedicular screw placement.

Authors:  Bidre N Upendra; Devkant Meena; Buddhadev Chowdhury; Abrar Ahmad; Arvind Jayaswal
Journal:  Spine (Phila Pa 1976)       Date:  2008-02-15       Impact factor: 3.468

3.  Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients.

Authors:  T Laine; K Mäkitalo; D Schlenzka; K Tallroth; M Poussa; A Alho
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis.

Authors:  U R Liljenqvist; H F Halm; T M Link
Journal:  Spine (Phila Pa 1976)       Date:  1997-10-01       Impact factor: 3.468

5.  Accuracy of pedicle screw placement in lumbar vertebrae.

Authors:  W H Castro; H Halm; J Jerosch; J Malms; J Steinbeck; S Blasius
Journal:  Spine (Phila Pa 1976)       Date:  1996-06-01       Impact factor: 3.468

6.  Thoracic pedicle screw fixation in spinal deformities: are they really safe?

Authors:  S I Suk; W J Kim; S M Lee; J H Kim; E R Chung
Journal:  Spine (Phila Pa 1976)       Date:  2001-09-15       Impact factor: 3.468

Review 7.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

Review 8.  Surgical treatment of traumatic fractures of the thoracic and lumbar spine: a systematic review of the literature on techniques, complications, and outcome.

Authors:  J J Verlaan; C H Diekerhof; E Buskens; I van der Tweel; A J Verbout; W J A Dhert; F C Oner
Journal:  Spine (Phila Pa 1976)       Date:  2004-04-01       Impact factor: 3.468

9.  Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases.

Authors:  E Sim
Journal:  Acta Orthop Scand       Date:  1993-02

10.  Reliability and Validity of the Swiss Spinal Stenosis Questionnaire for Iranian Patients with Lumbar Spinal Stenosis.

Authors:  Afshin Ahmadzadeh Heshmati; Moghaddameh Mirzaee
Journal:  Arch Bone Jt Surg       Date:  2018-03
View more