Literature DB >> 8295008

Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.

D A Weber1, M Ivanovic, D Franceschi, S E Strand, K Erlandsson, M Franceschi, H L Atkins, J A Coderre, H Susskind, T Button.   

Abstract

UNLABELLED: The performance of pinhole SPECT and the application of this technology to investigate the localization properties of radiopharmaceuticals in vivo in small laboratory animals are presented.
METHODS: System sensitivity and spatial resolution measurements of a rotating scintillation camera system are made for a low-energy pinhole collimator equipped with 1.0-, 2.0- and 3.3-mm aperture pinhole inserts. The spatial detail offered by pinhole SPECT for in vivo imaging was investigated in studies of the brain and heart in Fisher 344 rats by administering 201TICI, 99mTc-HMPAO, 99mTc-DTPA and 99mTc-MIBI. Image acquisition is performed using a rotating scintillation camera equipped with a pinhole collimator; projection data are acquired in conventional step-and-shoot mode as the camera is rotated 360 degrees around the subject. Pinhole SPECT images are reconstructed using a modified cone-beam algorithm developed from a two-dimensional fanbeam filtered backprojection algorithm.
RESULTS: The reconstructed transaxial resolution of 2.8 mm FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0-mm pinhole collimator aperture provide excellent spatial detail and adequate sensitivity for imaging the regional uptake of the radiopharmaceuticals in tumor, organs and other tissues in small laboratory animals.
CONCLUSION: The resolution properties of pinhole SPECT are superior to those which have been achieved thus far with conventional SPECT or PET imaging technologies. Pinhole SPECT provides an important approach for investigating localization properties of radiopharmaceuticals in vivo.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8295008

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  36 in total

Review 1.  Ultra-high-resolution imaging of small animals: implications for preclinical and research studies.

Authors:  D A Weber; M Ivanovic
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

Review 2.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

3.  Phantom experiments on a PSAPD-based compact gamma camera with submillimeter spatial resolution for small animal SPECT.

Authors:  Sangtaek Kim; Mickel McClish; Fares Alhassen; Youngho Seo; Kanai S Shah; Robert G Gould
Journal:  IEEE Trans Nucl Sci       Date:  2010-10       Impact factor: 1.679

4.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

5.  Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging.

Authors:  Keiichi Magota; Naoki Kubo; Yuji Kuge; Ken-Ichi Nishijima; Songji Zhao; Nagara Tamaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-12-10       Impact factor: 9.236

6.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

Review 7.  Emerging imaging techniques.

Authors:  Elliot R McVeigh
Journal:  Circ Res       Date:  2006-04-14       Impact factor: 17.367

8.  An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Authors:  Qiulin Tang; Gengsheng L Zeng; Qiu Huang
Journal:  Phys Med Biol       Date:  2006-11-09       Impact factor: 3.609

Review 9.  Use of tomographic nuclear medicine procedures, SPECT and pinhole SPECT, with cationic lipophilic radiotracers for the evaluation of axillary lymph node status in breast cancer patients.

Authors:  Giuseppe Madeddu; Angela Spanu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

10.  Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT.

Authors:  Greta S P Mok; Yong Du; Yuchuan Wang; Eric C Frey; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2009-09-25       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.