Literature DB >> 10385189

Ultra-high-resolution imaging of small animals: implications for preclinical and research studies.

D A Weber1, M Ivanovic.   

Abstract

Recent developments in the use of pinhole SPECT and dedicated PET for UHR small animal imaging have identified the technology that can be used to provide images with spatial resolution of the order of 1 to 3 mm. In SPECT imaging, rotating camera pinhole SPECT has provided the means to use existing equipment to achieve UHR images. It has the disadvantages of low sensitivity and requires special image software to reconstruct tomographic slices. However, with minimal additional cost to an imaging laboratory, pinhole SPECT can provide a quantitatively accurate imaging technique for small-animal studies. New detector technology offers considerable promise; however, more studies are required before any one system can be singled out as offering major advantages over the pinhole SPECT method for general purpose small-animal SPECT imaging. The search for the means to achieve better sensitivity with UHR continues. In PET imaging, with few exceptions, the general trend has been to design systems dedicated to small-animal imaging to achieve UHR images with satisfactory sensitivity for quantitative UHR imaging. Several of the ring configuration, small-animal PET imaging systems provide good sensitivity and high spatial resolution. The cost of many of these systems, however, is relatively high, and investigators continue to explore different detector materials and imaging geometries to develop an instrument with acceptable levels of sensitivity with UHR imaging capability. We believe that both small-animal SPECT and PET imaging techniques now offer practical UHR imaging methods for quantitative small-animal imaging. As these tools are implemented in the investigation of new radiopharmaceuticals, we expect the utility of in vivo small animal assays will support further research in optimizing this technology.

Mesh:

Substances:

Year:  1999        PMID: 10385189     DOI: 10.1016/s1071-3581(99)90046-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  15 in total

Review 1.  Review of convergent beam tomography in single photon emission computed tomography.

Authors:  G T Gullberg; G L Zeng; F L Datz; P E Christian; C H Tung; H T Morgan
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

2.  Beta camera for static and dynamic imaging of charged-particle emitting radionuclides in biologic samples.

Authors:  K Ljunggren; S E Strand
Journal:  J Nucl Med       Date:  1990-12       Impact factor: 10.057

Review 3.  Is there life after technetium: what is the potential for developing new broad-based radionuclides?

Authors:  S C Srivastava
Journal:  Semin Nucl Med       Date:  1996-04       Impact factor: 4.446

4.  Pinhole emission computed tomography: method and experimental evaluation.

Authors:  J Palmer; P Wollmer
Journal:  Phys Med Biol       Date:  1990-03       Impact factor: 3.609

Review 5.  From monoclonal antibodies to peptides and molecular recognition units: an overview.

Authors:  A N Serafini
Journal:  J Nucl Med       Date:  1993-03       Impact factor: 10.057

6.  Pinhole SPECT: ultra-high resolution imaging for small animal studies.

Authors:  D A Weber; M Ivanovic
Journal:  J Nucl Med       Date:  1995-12       Impact factor: 10.057

7.  The design and physical characteristics of a small animal positron emission tomograph.

Authors:  P M Bloomfield; S Rajeswaran; T J Spinks; S P Hume; R Myers; S Ashworth; K M Clifford; W F Jones; L G Byars; J Young
Journal:  Phys Med Biol       Date:  1995-06       Impact factor: 3.609

8.  A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation.

Authors:  J Li; R J Jaszczak; K L Greer; R E Coleman
Journal:  Phys Med Biol       Date:  1994-01       Impact factor: 3.609

9.  Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator.

Authors:  M Yukihiro; T Inoue; T Iwasaki; K Tomiyoshi; K Erlandsson; K Endo
Journal:  Eur J Nucl Med       Date:  1996-08

10.  Small animal imaging with pinhole single-photon emission computed tomography.

Authors:  S E Strand; M Ivanovic; K Erlandsson; D Franceschi; T Button; K Sjögren; D A Weber
Journal:  Cancer       Date:  1994-02-01       Impact factor: 6.860

View more
  18 in total

Review 1.  Imaging transgene expression with radionuclide imaging technologies.

Authors:  S S Gambhir; H R Herschman; S R Cherry; J R Barrio; N Satyamurthy; T Toyokuni; M E Phelps; S M Larson; J Balatoni; R Finn; M Sadelain; J Tjuvajev; R Blasberg
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  A new design for a SPECT small-animal imager.

Authors:  D W Wilson; H H Barrett; L R Furenlid
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2001-11-04

Review 4.  Imaging stem cells implanted in infarcted myocardium.

Authors:  Rong Zhou; Paul D Acton; Victor A Ferrari
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

Review 5.  Weaving single photon imaging into new drug development.

Authors:  P David Mozley
Journal:  Mol Imaging Biol       Date:  2005 Jan-Feb       Impact factor: 3.488

Review 6.  Emerging imaging techniques.

Authors:  Elliot R McVeigh
Journal:  Circ Res       Date:  2006-04-14       Impact factor: 17.367

7.  Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study.

Authors:  Christian Vanhove; Andriy Andreyev; Michel Defrise; Johan Nuyts; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-09-05       Impact factor: 9.236

8.  Will high-resolution/high-sensitivity SPECT ensure that PET is not the only survivor in nuclear medicine during the next decade?

Authors:  Alain Seret
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-14       Impact factor: 9.236

Review 9.  Modeling and imaging cardiac sympathetic neurodegeneration in Parkinson's disease.

Authors:  Valerie Joers; Marina E Emborg
Journal:  Am J Nucl Med Mol Imaging       Date:  2014-03-20

10.  Progression of detail.

Authors: 
Journal:  J Nucl Cardiol       Date:  2000-03       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.