Literature DB >> 19779896

Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT.

Greta S P Mok1, Yong Du, Yuchuan Wang, Eric C Frey, Benjamin M W Tsui.   

Abstract

PURPOSE: In this work, we developed and validated a Monte Carlo simulation (MCS) tool for investigation and evaluation of multi-pinhole (MPH) SPECT imaging. PROCEDURES: This tool was based on a combination of the SimSET and MCNP codes. Photon attenuation and scatter in the object, as well as penetration and scatter through the collimator detector, are modeled in this tool. It allows accurate and efficient simulation of MPH SPECT with focused pinhole apertures and user-specified photon energy, aperture material, and imaging geometry. The MCS method was validated by comparing the point response function (PRF), detection efficiency (DE), and image profiles obtained from point sources and phantom experiments. A prototype single-pinhole collimator and focused four- and five-pinhole collimators fitted on a small animal imager were used for the experimental validations. We have also compared computational speed among various simulation tools for MPH SPECT, including SimSET-MCNP, MCNP, SimSET-GATE, and GATE for simulating projections of a hot sphere phantom.
RESULTS: We found good agreement between the MCS and experimental results for PRF, DE, and image profiles, indicating the validity of the simulation method. The relative computational speeds for SimSET-MCNP, MCNP, SimSET-GATE, and GATE are 1: 2.73: 3.54: 7.34, respectively, for 120-view simulations. We also demonstrated the application of this MCS tool in small animal imaging by generating a set of low-noise MPH projection data of a 3D digital mouse whole body phantom.
CONCLUSIONS: The new method is useful for studying MPH collimator designs, data acquisition protocols, image reconstructions, and compensation techniques. It also has great potential to be applied for modeling the collimator-detector response with penetration and scatter effects for MPH in the quantitative reconstruction method.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19779896      PMCID: PMC3086288          DOI: 10.1007/s11307-009-0263-7

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  20 in total

Review 1.  Monte Carlo simulations in SPET and PET.

Authors:  I Buvat; I Castiglioni
Journal:  Q J Nucl Med       Date:  2002-03

Review 2.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

3.  Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.

Authors:  Fernando R Rannou; Vandana Kohli; David L Prout; Arion F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2004-10       Impact factor: 1.679

4.  A multipinhole small animal SPECT system with submillimeter spatial resolution.

Authors:  Tobias Funk; Philippe Després; William C Barber; Kanai S Shah; Bruce H Hasegawa
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

5.  Pinhole SPECT with different data acquisition geometries: usefulness of unified projection operators in homogeneous coordinates.

Authors:  Yuchuan Wang; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2007-03       Impact factor: 10.048

6.  Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

7.  The geometric transfer function for cone and fan beam collimators.

Authors:  B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1990-01       Impact factor: 3.609

8.  Improved estimation of the detector response function for converging beam collimators.

Authors:  E C Frey; B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

9.  Theoretical prediction of the geometric transfer function for focused collimators.

Authors:  C E Metz; M W Tsui; R N Beck
Journal:  J Nucl Med       Date:  1974-12       Impact factor: 10.057

10.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

View more
  2 in total

1.  Current pediatric administered activity guidelines for 99m Tc-DMSA SPECT based on patient weight do not provide the same task-based image quality.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Frederic Fahey; Yong Du; Xinhua Cao; Briana Sexton-Stallone; Justin Brown; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071