Literature DB >> 17110780

An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Qiulin Tang1, Gengsheng L Zeng, Qiu Huang.   

Abstract

To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novikov-type algorithm. The new algorithm is able to compensate for uniform attenuation, and computer simulation results show that reconstructed images are less noisy.

Mesh:

Year:  2006        PMID: 17110780      PMCID: PMC5314945          DOI: 10.1088/0031-9155/51/23/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

Review 1.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

2.  Design and simulation of a high-resolution stationary SPECT system for small animals.

Authors:  Freek J Beekman; Brendan Vastenhouw
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

3.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

4.  Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT.

Authors:  Qiulin Tang; Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2005-06-22       Impact factor: 3.609

5.  An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.

Authors:  Qiu Huang; Gengsheng L Zeng
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

6.  Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuation.

Authors:  T Inouye; K Kose; A Hasegawa
Journal:  Phys Med Biol       Date:  1989-03       Impact factor: 3.609

7.  U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.

Authors:  Freek J Beekman; Frans van der Have; Brendan Vastenhouw; Annemarie J A van der Linden; Peter P van Rijk; J Peter H Burbach; Marten P Smidt
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

8.  Ultra-high resolution SPECT system using four pinhole collimators for small animal studies.

Authors:  K Ishizu; T Mukai; Y Yonekura; M Pagani; T Fujita; Y Magata; S Nishizawa; N Tamaki; H Shibasaki; J Konishi
Journal:  J Nucl Med       Date:  1995-12       Impact factor: 10.057

9.  The use of filtering methods to compensate for constant attenuation in single-photon emission computed tomography.

Authors:  G T Gullberg; T F Budinger
Journal:  IEEE Trans Biomed Eng       Date:  1981-02       Impact factor: 4.538

10.  Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator.

Authors:  M Yukihiro; T Inoue; T Iwasaki; K Tomiyoshi; K Erlandsson; K Endo
Journal:  Eur J Nucl Med       Date:  1996-08
View more
  7 in total

1.  Analytic Derivation and Monte Carlo Validation of a Sensitivity Formula for Slit-Slit Collimation With Penetration.

Authors:  Ahmet S Ayan; Scott D Metzler; Roberto Accorsi
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-08       Impact factor: 1.679

2.  A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation.

Authors:  Jacob A Piatt; Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

3.  Noise-Weighted FBP Algorithm for Uniformly Attenuated SPECT Projections.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2016-06-23       Impact factor: 1.679

4.  High-Resolution Anamorphic SPECT Imaging.

Authors:  Heather L Durko; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2014-06       Impact factor: 1.679

5.  Adaptive SPECT imaging with crossed-slit apertures.

Authors:  Heather L Durko; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17

6.  High-resolution, anamorphic, adaptive small-animal SPECT imaging with silicon double-sided strip detectors.

Authors:  Heather L Durko; Todd E Peterson; Harrison H Barrett; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-08-21

7.  A skew-slit collimator for small-animal SPECT.

Authors:  Gengsheng L Zeng
Journal:  J Nucl Med Technol       Date:  2008-11-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.