Literature DB >> 7964766

High placement of porous-coated acetabular components in complex total hip arthroplasty.

S F Schutzer1, W H Harris.   

Abstract

The authors retrospectively evaluated the results of 56 hips in 51 patients with an acetabular deficiency who had a total hip arthroplasty with a porous-coated, cementless acetabular component implanted at a high hip center. Forty-nine cases were revisions and seven were primary operations. The mean height of the hip center was 43 mm above the interteardrop line compared to 14 mm for the anatomic center, threefold higher than normal. In contrast, the mean horizontal locus was reduced compared to normal (33 vs 37 mm for the anatomic center). Sixteen acetabular components were small (46-48 mm o.d.) and eight were miniature (40-44 mm o.d.). Despite superior placement of the acetabular component, 32 limbs were lengthened by the procedure. The mean preoperative Harris hip score was 51 (range, 28-93). At a mean follow-up period of 40 months (range, 24-64 months), the mean Harris hip score was 86 (range, 36-100). In 23 hips no radiolucent lines were present at the interface of the bone to the porous mesh, and 33 hips had a thin (0.5 mm), nonprogressive radiolucent line in one or more zones. No acetabular component had migrated and no problems occurred with the screws. Four hips (3 revisions and 1 primary operation) had a complete radiolucent line on one oblique view of the acetabulum. No acetabular component has been revised for loosening.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7964766     DOI: 10.1016/0883-5403(94)90045-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

Authors:  Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-08-29

2.  Acetabular revisions using a cementless oblong cup: five to ten year results.

Authors:  R Civinini; A Capone; C Carulli; M Villano; M I Gusso
Journal:  Int Orthop       Date:  2007-01-13       Impact factor: 3.075

Review 3.  [Musculoskeletal load analysis. A biomechanical explanation for clinical results--and more?].

Authors:  M O Heller; J H Schröder; G Matziolis; A Sharenkov; W R Taylor; C Perka; G N Duda
Journal:  Orthopade       Date:  2007-03       Impact factor: 1.087

4.  Acetabular cage survival and analysis of factors related to failure.

Authors:  Jonathan N Sembrano; Edward Y Cheng
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

5.  Type III acetabular defect revision with bilobed components: five-year results.

Authors:  Joseph T Moskal; Michael E Higgins; Joseph Shen
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

6.  Durable fixation achieved with medialized, high hip center cementless THAs for Crowe II and III dysplasia.

Authors:  Danyal H Nawabi; Morteza Meftah; Denis Nam; Amar S Ranawat; Chitranjan S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

7.  Restoration of the hip center during THA performed for protrusio acetabuli is associated with better implant survival.

Authors:  Yaser M K Baghdadi; A Noelle Larson; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2013-05-24       Impact factor: 4.176

Review 8.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

9.  Outcome of cages in revision arthroplasty of the acetabulum: a systematic review.

Authors:  Alessandro Aprato; Matteo Olivero; Luigi Branca Vergano; Alessandro Massè
Journal:  Acta Biomed       Date:  2019-01-10

10.  Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup.

Authors:  Martín A Buttaro; Fernando Comba; Rodolfo Pusso; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

View more