Literature DB >> 7640545

Pulse oximetry: a practical review.

C D Hanning1, J M Alexander-Williams.   

Abstract

Mesh:

Year:  1995        PMID: 7640545      PMCID: PMC2550433          DOI: 10.1136/bmj.311.7001.367

Source DB:  PubMed          Journal:  BMJ        ISSN: 0959-8138


× No keyword cloud information.
  17 in total

Review 1.  Pulse oximetry. Uses and abuses.

Authors:  L M Schnapp; N H Cohen
Journal:  Chest       Date:  1990-11       Impact factor: 9.410

Review 2.  Potential errors in pulse oximetry. I. Pulse oximeter evaluation.

Authors:  A C Ralston; R K Webb; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

Review 3.  Respiratory monitoring.

Authors:  M J Tobin
Journal:  JAMA       Date:  1990-07-11       Impact factor: 56.272

Review 4.  Principles of pulse oximetry: theoretical and practical considerations.

Authors:  C M Alexander; L E Teller; J B Gross
Journal:  Anesth Analg       Date:  1989-03       Impact factor: 5.108

Review 5.  Pulse oximetry.

Authors:  K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

6.  A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion.

Authors:  D G Clayton; R K Webb; A C Ralston; D Duthie; W B Runciman
Journal:  Anaesthesia       Date:  1991-01       Impact factor: 6.955

7.  Neonatal pulse oximetry: accuracy and reliability.

Authors:  W W Hay; J M Brockway; M Eyzaguirre
Journal:  Pediatrics       Date:  1989-05       Impact factor: 7.124

Review 8.  Pulse oximetry versus arterial blood gas specimens in long-term oxygen therapy.

Authors:  D J Pierson
Journal:  Lung       Date:  1990       Impact factor: 2.584

Review 9.  Limitations of pulse oximetry.

Authors:  G Mardirossian; R E Schneider
Journal:  Anesth Prog       Date:  1992

Review 10.  Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality.

Authors:  R K Webb; A C Ralston; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

View more
  19 in total

1.  Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

Authors:  M Shafique; P A Kyriacou; S K Pal
Journal:  Med Biol Eng Comput       Date:  2012-05-04       Impact factor: 2.602

2.  Pulse oximetry in primary care: primary care diagnostic technology update.

Authors:  Annette Plüddemann; Matthew Thompson; Carl Heneghan; Christopher Price
Journal:  Br J Gen Pract       Date:  2011-05       Impact factor: 5.386

3.  The incidence of hypoxemia during surgery: evidence from two institutions.

Authors:  Jesse M Ehrenfeld; Luke M Funk; Johan Van Schalkwyk; Alan F Merry; Warren S Sandberg; Atul Gawande
Journal:  Can J Anaesth       Date:  2010-07-31       Impact factor: 5.063

4.  Practical pulse oximetry. Saturation can be normal with dangerously high pCO2.

Authors:  P M Robbins; M D Brunner
Journal:  BMJ       Date:  1995-11-11

5.  Practical pulse oximetry. Overnight oximetry is easy and useful.

Authors:  P C Deegan; R Liston
Journal:  BMJ       Date:  1995-11-11

6.  Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns.

Authors:  A Kaya; M Okur; E Sal; E Peker; M Köstü; O Tuncer; E Kırımi
Journal:  West Indian Med J       Date:  2014-09-03       Impact factor: 0.171

Review 7.  Safe paediatric intensive care. Part 1: Does more medical care lead to improved outcome?

Authors:  Bernhard Frey; Andrew Argent
Journal:  Intensive Care Med       Date:  2004-04-22       Impact factor: 17.440

8.  Apnoea and bradycardia during epileptic seizures: relation to sudden death in epilepsy.

Authors:  L Nashef; F Walker; P Allen; J W Sander; S D Shorvon; D R Fish
Journal:  J Neurol Neurosurg Psychiatry       Date:  1996-03       Impact factor: 10.154

9.  Multispectral oximetry of murine tendon microvasculature with inflammation.

Authors:  Marieke A van der Putten; James M Brewer; Andrew R Harvey
Journal:  Biomed Opt Express       Date:  2017-05-08       Impact factor: 3.732

10.  Non-contact measurement of oxygen saturation with an RGB camera.

Authors:  Alessandro R Guazzi; Mauricio Villarroel; João Jorge; Jonathan Daly; Matthew C Frise; Peter A Robbins; Lionel Tarassenko
Journal:  Biomed Opt Express       Date:  2015-08-11       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.