Literature DB >> 2717288

Neonatal pulse oximetry: accuracy and reliability.

W W Hay1, J M Brockway, M Eyzaguirre.   

Abstract

Pulse oximetry has gained widespread use in neonatal oxygen monitoring. However, because specific morbidity in neonates has been related to abnormal levels of oxygen partial pressure (PaO2), it is essential to demonstrate that pulse oxygen saturation values (SpO2) are highly accurate and reflect with precision the simultaneous PaO2. In this report, data is presented that describe the accuracy of the Ohmeda Biox 3700 pulse oximeter. SpO2 was highly correlated with arterial blood oxygen saturation (r = .99) measured on arterial (catheter) blood using a two-wavelength Radiometer OSM2 Hemoximeter. When compared with PaO2, SpO2 values of 92% +/- 3% (mean +/- range) excluded all of the measured PaO2 values less than 45 mm Hg and greater than 100 mm Hg. SpO2-tcPO2 (transcutaneous PO2) and SpO2-PaO2 (catheter or percutaneous arterial PO2) correlations showed that bronchopulmonary dysplasia, percutaneous arterial sampling, and nipple feeding skewed the tcPO2 but not the PaO2 correlations with SpO2, indicating that SpO2 is not sensitive to peripheral factors that affect tcPO2. SpO2-PaO2 correlation was not affected by gestational age. A high degree of accuracy of SpO2 values and SpO2 prediction of normal appearing PaO2 values are defined by these results.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2717288

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  22 in total

1.  Individualised pulse oximetry limits in neonatal intensive care.

Authors:  R Gupta; C W Yoxall; N Subhedar; N J Shaw
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-11       Impact factor: 5.747

Review 2.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

3.  Considerations in the surgical treatment of congenital heart disease in children of Jehovah's Witnesses.

Authors:  D A Cooley; C M Burnett
Journal:  Tex Heart Inst J       Date:  1992

4.  Pulse oximetry used for documenting oxygen saturation and right-to-left shunting immediately after birth.

Authors:  P Meier-Stauss; H U Bucher; R Hürlimann; V König; R Huch
Journal:  Eur J Pediatr       Date:  1990-09       Impact factor: 3.183

Review 5.  Bronchopulmonary dysplasia: a new look at management.

Authors:  D P Southall; M P Samuels
Journal:  Arch Dis Child       Date:  1990-10       Impact factor: 3.791

6.  Oxygen saturation and breathing patterns in infancy. 1: Full term infants in the second month of life.

Authors:  V A Stebbens; C F Poets; J R Alexander; W A Arrowsmith; D P Southall
Journal:  Arch Dis Child       Date:  1991-05       Impact factor: 3.791

Review 7.  Pulse oximetry for monitoring infants in the delivery room: a review.

Authors:  J A Dawson; P G Davis; C P F O'Donnell; C O F Kamlin; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-01       Impact factor: 5.747

8.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

9.  A procedure for determining subject-specific pulse oxygen saturation response.

Authors:  Kyle M Burk; Joseph A Orr
Journal:  Med Biol Eng Comput       Date:  2020-01-27       Impact factor: 2.602

10.  Pulse oximetry reference values at high altitude.

Authors:  J M Lozano; O R Duque; T Buitrago; S Behaine
Journal:  Arch Dis Child       Date:  1992-03       Impact factor: 3.791

View more