Limitations of pulse oximetry.

G Mardirossian1, R E Schneider.   

Abstract

Pulse oximetry is a noninvasive, accurate, and safe method for the measurement of oxygen saturation during intravenous sedation or general anesthesia. Several factors should be considered with its use, since these variables will either alter the accuracy of the readings or may cause harm to the patient. These factors include changes in the strength of the arterial pulse, body movements, dyshemoglobinemias, plasma lipids and bilirubin, color interferences, venous pulsations, and several physical factors. Awareness of these variations will help the clinician become more knowledgeable in the use of the pulse oximeter.

Entities:  

Mesh:

Year:  1992        PMID: 8250340      PMCID: PMC2148612     

Source DB:  PubMed          Journal:  Anesth Prog        ISSN: 0003-3006


  6 in total

Review 1.  Pulse oximetry.

Authors:  K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

2.  Pulse oximeter in the dental surgery.

Authors:  H Lopert
Journal:  Anesth Prog       Date:  1989 Jul-Oct

3.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

4.  Pulse oximetry: evaluation of accuracy during outpatient general anesthesia for oral surgery.

Authors:  J A Anderson; D M Lambert; E R Kafer; P Dolan
Journal:  Anesth Prog       Date:  1988 Mar-Apr

5.  Arterial oxygen desaturation in adult dental patients receiving conscious sedation.

Authors:  A R Hovagim; S A Vitkun; G R Manecke; R Reiner
Journal:  J Oral Maxillofac Surg       Date:  1989-09       Impact factor: 1.895

6.  Finger injury resulting from pulse oximeter probe during orthognathic surgery.

Authors:  P D Chemello; S R Nelson; L M Wolford
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1990-02
  6 in total
  12 in total

1.  Clinical Characteristics and Outcomes Are Similar in ARDS Diagnosed by Oxygen Saturation/Fio2 Ratio Compared With Pao2/Fio2 Ratio.

Authors:  Wei Chen; David R Janz; Ciara M Shaver; Gordon R Bernard; Julie A Bastarache; Lorraine B Ware
Journal:  Chest       Date:  2015-12       Impact factor: 9.410

Review 2.  Pulse oximetry: a practical review.

Authors:  C D Hanning; J M Alexander-Williams
Journal:  BMJ       Date:  1995-08-05

3.  Wearable speckle plethysmography (SPG) for characterizing microvascular flow and resistance.

Authors:  Michael Ghijsen; Tyler B Rice; Bruce Yang; Sean M White; Bruce J Tromberg
Journal:  Biomed Opt Express       Date:  2018-07-30       Impact factor: 3.732

Review 4.  Imaging in Chronic Wound Diagnostics.

Authors:  Shuxin Li; Ali H Mohamedi; Jon Senkowsky; Ashwin Nair; Liping Tang
Journal:  Adv Wound Care (New Rochelle)       Date:  2020-03-19       Impact factor: 4.730

5.  Simultaneous assessment of red blood cell aggregation and oxygen saturation under pulsatile flow using high-frequency photoacoustics.

Authors:  Tae-Hoon Bok; Eno Hysi; Michael C Kolios
Journal:  Biomed Opt Express       Date:  2016-06-23       Impact factor: 3.732

6.  Inhaled nitric oxide does not improve maximal oxygen consumption in endurance trained and untrained healthy individuals.

Authors:  Andrew R Brotto; Devin B Phillips; Victoria L Meah; Bryan A Ross; Desi P Fuhr; Rhys I Beaudry; Sean van Diepen; Michael K Stickland
Journal:  Eur J Appl Physiol       Date:  2022-01-22       Impact factor: 3.078

7.  Monitoring in the intensive care.

Authors:  Eric Kipnis; Davinder Ramsingh; Maneesh Bhargava; Erhan Dincer; Maxime Cannesson; Alain Broccard; Benoit Vallet; Karim Bendjelid; Ronan Thibault
Journal:  Crit Care Res Pract       Date:  2012-08-27

8.  Unanticipated Respiratory Compromise and Unplanned Intubations on General Medical and Surgical Floors.

Authors:  Armando D Bedoya; Nrupen A Bhavsar; Bhargav Adagarla; Courtney B Page; Benjamin A Goldstein; Neil R MacIntyre
Journal:  Respir Care       Date:  2020-03-10       Impact factor: 2.339

9.  A cohort study to identify simple clinical tests for chronic respiratory failure in obese patients with sleep-disordered breathing.

Authors:  S Mandal; E S Suh; E Boleat; W Asher; M Kamalanathan; K Lee; A Douiri; P B Murphy; J Steier; N Hart
Journal:  BMJ Open Respir Res       Date:  2014-04-10

10.  Pulse oximeter oxygen saturation in prediction of arterial oxygen saturation in liver transplant candidates.

Authors:  Seiyed Mohammad Ali Ghayumi; Abolfazl Khalafi-Nezhad; Zahra Jowkar
Journal:  Hepat Mon       Date:  2014-04-07       Impact factor: 0.660

View more