Literature DB >> 22555629

Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

M Shafique1, P A Kyriacou, S K Pal.   

Abstract

Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p < 0.05) than the AC PPG signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22555629     DOI: 10.1007/s11517-012-0910-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship.

Authors:  Jaak Talts; Rein Raamat; Kersti Jagomägi
Journal:  Med Biol Eng Comput       Date:  2006-08-03       Impact factor: 2.602

2.  A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion.

Authors:  Muhammad Shafique; Justin P Phillips; Panayiotis A Kyriacou
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

3.  A new method of screening for diabetic neuropathy using laser Doppler and photoplethysmography.

Authors:  Sung Woo Kim; Soo Chan Kim; Ki Chang Nam; Eun Seok Kang; Jae Jung Im; Deok Won Kim
Journal:  Med Biol Eng Comput       Date:  2007-10-10       Impact factor: 2.602

Review 4.  Pulse oximetry: a practical review.

Authors:  C D Hanning; J M Alexander-Williams
Journal:  BMJ       Date:  1995-08-05

Review 5.  Pulse oximetry: principles and limitations.

Authors:  J E Sinex
Journal:  Am J Emerg Med       Date:  1999-01       Impact factor: 2.469

6.  Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation.

Authors:  P A Kyriacou; A R Moye; D M Choi; R M Langford; D P Jones
Journal:  Physiol Meas       Date:  2001-02       Impact factor: 2.833

Review 7.  Recent advances in non-invasive assessment of human skin blood flow.

Authors:  P G Agache; A S Dupond
Journal:  Acta Derm Venereol Suppl (Stockh)       Date:  1994

8.  Peripheral photoplethysmography variability analysis of sepsis patients.

Authors:  Paul M Middleton; Collin H H Tang; Gregory S H Chan; Sarah Bishop; Andrey V Savkin; Nigel H Lovell
Journal:  Med Biol Eng Comput       Date:  2010-12-14       Impact factor: 2.602

Review 9.  Optical techniques in the assessment of peripheral arterial disease.

Authors:  Mohamad E Alnaeb; Nasser Alobaid; Alexander M Seifalian; Dimitri P Mikhailidis; George Hamilton
Journal:  Curr Vasc Pharmacol       Date:  2007-01       Impact factor: 2.719

10.  Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

Authors:  Gavin D Perkins; Daniel F McAuley; Simon Giles; Helen Routledge; Fang Gao
Journal:  Crit Care       Date:  2003-06-11       Impact factor: 9.097

View more
  4 in total

1.  Differential effects of the blood pressure state on pulse rate variability and heart rate variability in critically ill patients.

Authors:  Elisa Mejía-Mejía; James M May; Mohamed Elgendi; Panayiotis A Kyriacou
Journal:  NPJ Digit Med       Date:  2021-05-14

2.  In vivo investigation of ear canal pulse oximetry during hypothermia.

Authors:  K Budidha; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-01-27       Impact factor: 2.502

3.  Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

Authors:  T Y Abay; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-05-25       Impact factor: 2.502

Review 4.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.