Literature DB >> 2014898

Potential errors in pulse oximetry. I. Pulse oximeter evaluation.

A C Ralston1, R K Webb, W B Runciman.   

Abstract

There is no absolute reference for oxygen saturation, although multiwavelength in vitro oximeters are accepted as the 'gold standard'. Regardless of whether fractional or functional saturation is used by manufacturers to calibrate their oximeters, evaluation against fractional saturation is recommended since this is the clinically relevant variable. The use of standard notation and comparisons based on bias and precision is recommended. The accuracy of pulse oximetry is intrinsically limited by the use of only two wavelengths, and is dependent on the initial calibration population. The empirical algorithms used to convert the signal to its 'readout value' and the quality control of hardware may both be important sources of variability between oximeters. Change in blood temperature may introduce errors in pulse oximeter and in vitro oximeter saturation readings, but these will be clinically insignificant. Changes in blood pH should not decrease pulse oximetry accuracy.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2014898     DOI: 10.1111/j.1365-2044.1991.tb09410.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  24 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

Review 3.  Pulse oximetry: a practical review.

Authors:  C D Hanning; J M Alexander-Williams
Journal:  BMJ       Date:  1995-08-05

Review 4.  Continuous intra-arterial blood gas monitoring.

Authors:  B Venkatesh; S P Hendry
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

5.  Effect of Incentive Spirometry on Postoperative Hypoxemia and Pulmonary Complications After Bariatric Surgery: A Randomized Clinical Trial.

Authors:  Haddon Pantel; John Hwang; David Brams; Thomas Schnelldorfer; Dmitry Nepomnayshy
Journal:  JAMA Surg       Date:  2017-05-01       Impact factor: 14.766

6.  Correlation Between PaO2/FIO2 and Peripheral Capillary Oxygenation/FIO2 in Burned Children With Smoke Inhalation Injury.

Authors:  Janos Cambiaso-Daniel; Charles D Voigt; Eric Rivas; Gabriel Hundeshagen; Omar Nunez-Lopez; Lars-Peter Kamolz; Michaela Sljivich; Linda E Sousse; David N Herndon; Oscar E Suman; Michael P Kinsky; Ronald P Mlcak
Journal:  Pediatr Crit Care Med       Date:  2017-10       Impact factor: 3.624

7.  NADH-diaphorase deficiency identified in a patient with congenital methaemoglobinaemia detected by pulse oximetry.

Authors:  K Sugahara; T Sadohara; T Kawaguchi; T Hirano
Journal:  Intensive Care Med       Date:  1998-07       Impact factor: 17.440

8.  Cigarette smoke exposure worsens acute lung injury in antibiotic-treated bacterial pneumonia in mice.

Authors:  Jeffrey E Gotts; Lauren Chun; Jason Abbott; Xiaohui Fang; Naoki Takasaka; Stephen L Nishimura; Matthew L Springer; Suzaynn F Schick; Carolyn S Calfee; Michael A Matthay
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2018-03-15       Impact factor: 5.464

9.  Arterial blood gas analysis or oxygen saturation in the assessment of acute asthma?

Authors:  D M Carruthers; B D Harrison
Journal:  Thorax       Date:  1995-02       Impact factor: 9.139

10.  The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study.

Authors:  Ben J Wilson; Hamish J Cowan; Jason A Lord; Dan J Zuege; David A Zygun
Journal:  BMC Emerg Med       Date:  2010-05-05
View more