Literature DB >> 26417504

Non-contact measurement of oxygen saturation with an RGB camera.

Alessandro R Guazzi1, Mauricio Villarroel1, João Jorge1, Jonathan Daly1, Matthew C Frise2, Peter A Robbins2, Lionel Tarassenko1.   

Abstract

A novel method (Sophia) is presented to track oxygen saturation changes in a controlled environment using an RGB camera placed approximately 1.5 m away from the subject. The method is evaluated on five healthy volunteers (Fitzpatrick skin phenotypes II, III, and IV) whose oxygen saturations were varied between 80% and 100% in a purpose-built chamber over 40 minutes each. The method carefully selects regions of interest (ROI) in the camera image by calculating signal-to-noise ratios for each ROI. This allows it to track changes in oxygen saturation accurately with respect to a conventional pulse oximeter (median coefficient of determination, 0.85).

Entities:  

Keywords:  (170.0110) Imaging systems; (170.0170) Medical optics and biotechnology; (170.1460) Blood gas monitoring; (170.1470) Blood or tissue constituent monitoring; (170.3660) Light propagation in tissues; (280.0280) Remote sensing and sensors

Year:  2015        PMID: 26417504      PMCID: PMC4574660          DOI: 10.1364/BOE.6.003320

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  22 in total

1.  Contactless multiple wavelength photoplethysmographic imaging: a first step toward "SpO2 camera" technology.

Authors:  F P Wieringa; F Mastik; A F W van der Steen
Journal:  Ann Biomed Eng       Date:  2005-08       Impact factor: 3.934

Review 2.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

3.  Takuo Aoyagi: discovery of pulse oximetry.

Authors:  John W Severinghaus
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

4.  Visualizing of skin chromophore concentrations by use of RGB images.

Authors:  Izumi Nishidate; Kiyohiro Sasaoka; Testuya Yuasa; Kyuichi Niizeki; Takaaki Maeda; Yoshihisa Aizu
Journal:  Opt Lett       Date:  2008-10-01       Impact factor: 3.776

5.  DistancePPG: Robust non-contact vital signs monitoring using a camera.

Authors:  Mayank Kumar; Ashok Veeraraghavan; Ashutosh Sabharwal
Journal:  Biomed Opt Express       Date:  2015-04-06       Impact factor: 3.732

6.  Variations in optical absorption spectra of adult and fetal hemoglobins and its effect on pulse oximetry.

Authors:  Y Mendelson; J C Kent
Journal:  IEEE Trans Biomed Eng       Date:  1989-08       Impact factor: 4.538

7.  Chamber for controlling end-tidal gas tensions over sustained periods in humans.

Authors:  L S Howard; R A Barson; B P Howse; T R McGill; M E McIntyre; D F O'Connor; P A Robbins
Journal:  J Appl Physiol (1985)       Date:  1995-03

8.  Non-contact estimation of heart rate and oxygen saturation using ambient light.

Authors:  Ufuk Bal
Journal:  Biomed Opt Express       Date:  2014-12-10       Impact factor: 3.732

9.  Remote plethysmographic imaging using ambient light.

Authors:  Wim Verkruysse; Lars O Svaasand; J Stuart Nelson
Journal:  Opt Express       Date:  2008-12-22       Impact factor: 3.894

10.  Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy.

Authors:  David A Benaron; Ilian H Parachikov; Shai Friedland; Roy Soetikno; John Brock-Utne; Peter J A van der Starre; Camran Nezhat; Martha K Terris; Peter G Maxim; Jeffrey J L Carson; Mahmood K Razavi; Hayes B Gladstone; Edgar F Fincher; Christopher P Hsu; F Landon Clark; Wai-Fung Cheong; Joshua L Duckworth; David K Stevenson
Journal:  Anesthesiology       Date:  2004-06       Impact factor: 7.892

View more
  18 in total

1.  Skin inhomogeneity as a source of error in remote PPG-imaging.

Authors:  Andreia Vieira Moço; Sander Stuijk; Gerard de Haan
Journal:  Biomed Opt Express       Date:  2016-10-26       Impact factor: 3.732

2.  Analysis of CNN-based remote-PPG to understand limitations and sensitivities.

Authors:  Qi Zhan; Wenjin Wang; Gerard de Haan
Journal:  Biomed Opt Express       Date:  2020-02-07       Impact factor: 3.732

3.  Novel health monitoring method using an RGB camera.

Authors:  M A Hassan; A S Malik; D Fofi; N Saad; F Meriaudeau
Journal:  Biomed Opt Express       Date:  2017-10-04       Impact factor: 3.732

Review 4.  Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Authors:  Haythem Rehouma; Rita Noumeir; Sandrine Essouri; Philippe Jouvet
Journal:  Sensors (Basel)       Date:  2020-12-17       Impact factor: 3.576

5.  New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

Authors:  Mark van Gastel; Sander Stuijk; Gerard de Haan
Journal:  Sci Rep       Date:  2016-12-07       Impact factor: 4.379

6.  Unobtrusive Vital Sign Monitoring in Automotive Environments-A Review.

Authors:  Steffen Leonhardt; Lennart Leicht; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

Review 7.  Unobtrusive Health Monitoring in Private Spaces: The Smart Vehicle.

Authors:  Ju Wang; Joana M Warnecke; Mostafa Haghi; Thomas M Deserno
Journal:  Sensors (Basel)       Date:  2020-04-25       Impact factor: 3.576

8.  Calibration of Contactless Pulse Oximetry.

Authors:  Wim Verkruysse; Marek Bartula; Erik Bresch; Mukul Rocque; Mohammed Meftah; Ihor Kirenko
Journal:  Anesth Analg       Date:  2017-01       Impact factor: 5.108

9.  Camera-based photoplethysmography in an intraoperative setting.

Authors:  Alexander Trumpp; Johannes Lohr; Daniel Wedekind; Martin Schmidt; Matthias Burghardt; Axel R Heller; Hagen Malberg; Sebastian Zaunseder
Journal:  Biomed Eng Online       Date:  2018-03-14       Impact factor: 2.819

Review 10.  Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors.

Authors:  Ammar Ahmad Tarar; Umair Mohammad; Soumya K Srivastava
Journal:  Biosensors (Basel)       Date:  2020-05-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.