Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.

R H Epstein1, S Huffnagle, R R Bartkowski.   

Abstract

A noninvasive blood pressure monitor (Finapres) that uses the methodology of Penaz to continuously display the arterial waveform from the finger has been introduced recently. The Finapres monitor overestimated systolic pressure by 5.8 +/- 11.9 mm Hg, while the Dinamap monitor underestimated systolic pressure by -6.9 +/- 9.2 mm Hg (P = 0.003). Dinamap mean and diastolic pressure biases were less than 2 mm Hg, while the Finapres biases for these variables were significantly greater (7.7 +/- 10.0 and 8.2 +/- 9.8 mm Hg, respectively). There was no difference in systolic or mean pressure precision between the two devices (approximately 10 mm Hg), but the diastolic precision of the Dinamap unit was superior to that of the Finapres. While in most patients the Finapres monitor provided continuous blood pressure data equivalent to the data from the radial artery, marked bias (greater than 15 mm Hg) was exhibited in 2 patients for all three pressure variables. Despite this bias, blood pressure changes were tracked closely in these 2 patients. We conclude that, in its current form, the Finapres monitor cannot be relied upon independently to accurately measure blood pressure in patients undergoing general anesthesia. Since the Dinamap monitor measures mean pressure reliably and accurately, we suggest that mean blood pressure values between the Finapres and Dinamap monitors be compared to guide one in interpreting Finapres data.

Entities:  

Mesh:

Year:  1991        PMID: 2072129     DOI: 10.1007/BF01618116

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  14 in total

1.  Experimental analysis of catheter-manometer systems in vitro and in vivo.

Authors:  S F Hipkins; A J Rutten; W B Runciman
Journal:  Anesthesiology       Date:  1989-12       Impact factor: 7.892

2.  Oscillometric blood pressure determination from the adult thumb using an infant cuff.

Authors:  M S Gorback; T J Quill; E C Bloch; D A Graubert
Journal:  Anesth Analg       Date:  1989-11       Impact factor: 5.108

3.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

4.  Evaluation of the Dinamap continuous blood pressure monitor.

Authors:  T A Manolio; S C Fishel; C Beattie; J Torres; R Christopherson; W T Merritt; P K Whelton
Journal:  Am J Hypertens       Date:  1988-07       Impact factor: 2.689

5.  Comparison of intra-arterial and automated oscillometric blood pressure measurement methods in postoperative hypertensive patients.

Authors:  P G Loubser
Journal:  Med Instrum       Date:  1986 Sep-Oct

6.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

Review 7.  Comparison of direct and indirect measuring arterial blood pressure.

Authors:  J M Bruner; L J Krenis; J M Kunsman; A P Sherman
Journal:  Med Instrum       Date:  1981 Jan-Feb

8.  Some suggestions for measuring predictive performance.

Authors:  L B Sheiner; S L Beal
Journal:  J Pharmacokinet Biopharm       Date:  1981-08

9.  Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres).

Authors:  J C Dorlas; J A Nijboer; W T Butijn; G M van der Hoeven; J J Settels; K H Wesseling
Journal:  Anesthesiology       Date:  1985-03       Impact factor: 7.892

10.  Evaluation of a continuous noninvasive blood pressure monitor in obstetric patients undergoing spinal anesthesia.

Authors:  R H Epstein; S Kaplan; B L Leighton; M C Norris; C A DeSimone
Journal:  J Clin Monit       Date:  1989-07
View more
  4 in total

1.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure.

Authors:  P D Baker; D R Westenskow; K Kück
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

2.  Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

Authors:  C C Young; J B Mark; W White; A DeBree; J S Vender; A Fleming
Journal:  J Clin Monit       Date:  1995-07

3.  Comparison of intraarterial with continuous noninvasive blood pressure measurement in postoperative pediatric patients.

Authors:  J K Triedman; J P Saul
Journal:  J Clin Monit       Date:  1994-01

4.  Autonomic dysfunction in patients with advanced cancer; prevalence, clinical correlates and challenges in assessment.

Authors:  Carol A Stone; Rose Anne Kenny; Brid Nolan; Peter G Lawlor
Journal:  BMC Palliat Care       Date:  2012-03-01       Impact factor: 3.234

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.