Literature DB >> 24062012

Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy.

Jens Spießhöfer1, Jessica Heinrich, Thomas Bitter, Christina Efken, Roman Lehmann, Siegfried Eckert, Dieter Horstkotte, Olaf Oldenburg.   

Abstract

PURPOSE: Using pulse transit time (PTT) and an ECG appears to be a promising alternative for invasive or noninvasive monitoring of blood pressure (BP). This study assessed the validity of PTT for BP monitoring in clinical practice.
METHODS: Twenty-nine patients with chronic heart failure (HF; 27 male, 70.5 ± 9.9 years) and nocturnal Cheyne-Stokes respiration were noninvasively ventilated for one hour using adaptive servoventilation (ASV) therapy (PaceWave, ResMed). BP was measured using two devices (oscillometrically via Task Force Monitor, CNSystems and PTT via SOMNOscreen, Somnomedics) at least every 7 min for 30 min before, during, and after ASV.
RESULTS: Mean systolic BP was 118.1 ± 14.4 mmHg vs. 115.9 ± 14.1 mmHg for oscillometric method vs PTT, respectively. Corresponding values for diastolic BP were 72.3 ± 10.3 mmHg and 69.4 ± 11.1 mmHg. While clinically comparable, differences between the two methods were statistically significant (p < 0.05). The difference between the two methods showed an increasing trend over time. A total of 18.5 % of PTT-based measurements could not be analyzed. The direction of a change in BP was opposite for PTT vs oscillometry for 17.0 % and 32.8 % of systolic and diastolic BP measurements, respectively.
CONCLUSIONS: When monitoring BP in HF patients, overall BP monitoring using PTT is comparable to oscillometry for a period of 2 h (including a 1-h ASV phase). However, PTT shows a tendency to underestimate BP over time and during ASV.

Entities:  

Mesh:

Year:  2013        PMID: 24062012     DOI: 10.1007/s11325-013-0895-3

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  32 in total

1.  Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults.

Authors:  Eoin O'Brien; Thomas Pickering; Roland Asmar; Martin Myers; Gianfranco Parati; Jan Staessen; Thomas Mengden; Yutaka Imai; Bernard Waeber; Paolo Palatini; William Gerin
Journal:  Blood Press Monit       Date:  2002-02       Impact factor: 1.444

2.  Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation.

Authors:  Heidi Schmalgemeier; Thomas Bitter; Stephan Bartsch; Kevin Bullert; Thomas Fischbach; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2011-10-29       Impact factor: 2.816

Review 3.  Pulse wave analysis and pulse wave velocity: a review of blood pressure interpretation 100 years after Korotkov.

Authors:  Kozo Hirata; Masanobu Kawakami; Michael F O'Rourke
Journal:  Circ J       Date:  2006-10       Impact factor: 2.993

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Evaluation of blood pressure changes using vascular transit time.

Authors:  Jong Yong Abdiel Foo; Chu Sing Lim; Ping Wang
Journal:  Physiol Meas       Date:  2006-05-26       Impact factor: 2.833

Review 6.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

7.  Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

Authors:  C C Young; J B Mark; W White; A DeBree; J S Vender; A Fleming
Journal:  J Clin Monit       Date:  1995-07

8.  A computer program for the peripheral pulse wave.

Authors:  E M Simmons; H Leader; S A Friedman; B Davis; D Lee; T Winsor; C A Caceres
Journal:  Am J Cardiol       Date:  1967-06       Impact factor: 2.778

9.  Obstructive sleep apnea as a risk factor for coronary events or cardiovascular death.

Authors:  Neomi A Shah; Henry Klar Yaggi; John Concato; Vahid Mohsenin
Journal:  Sleep Breath       Date:  2009-09-24       Impact factor: 2.816

10.  A brief journey into the history of the arterial pulse.

Authors:  Nima Ghasemzadeh; A Maziar Zafari
Journal:  Cardiol Res Pract       Date:  2011-07-28       Impact factor: 1.866

View more
  4 in total

1.  Validity of transit time-based blood pressure measurements in patients with and without heart failure or pulmonary arterial hypertension across different breathing maneuvers.

Authors:  Sara Becker; Jens Spiesshoefer; Tobias Brix; Izabela Tuleta; Michael Mohr; Michele Emdin; Matthias Boentert; Alberto Giannoni
Journal:  Sleep Breath       Date:  2019-05-02       Impact factor: 2.816

2.  Noninvasive ventilation improves cardiac function in patients with chronic heart failure.

Authors:  Jing Cheng; Yanping Liu; Guishuang Li; Zhongwen Zhang; Lianyue Ma; Xiaoyan Yang; Jianmin Yang; Kai Zhang; Jing Kong; Mei Dong; Meng Zhang; Xingli Xu; Wenhai Sui; Jiali Wang; Rui Shang; Xiaoping Ji; Yun Zhang; Cheng Zhang; Panpan Hao
Journal:  Oncotarget       Date:  2016-08-02

3.  Wearable Pulse Wave Monitoring System Based on MEMS Sensors.

Authors:  Yu Sun; Ying Dong; Ruyi Gao; Yao Chu; Min Zhang; Xiang Qian; Xiaohao Wang
Journal:  Micromachines (Basel)       Date:  2018-02-23       Impact factor: 2.891

Review 4.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

  4 in total