Literature DB >> 8458649

National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.

W B White1, A S Berson, C Robbins, M J Jamieson, L M Prisant, E Roccella, S G Sheps.   

Abstract

The Association for the Advancement of Medical Instrumentation develops voluntary standards for medical devices so that manufacturers might provide information on their product and basic safety and performance criteria that should be considered in qualifying the instrument for clinical use. American national standards are generated through a consensus process by committees consisting of experts in research, development, and design from user, industry, and government communities. Draft standards are made available for public review and may become American national standards after review by the American National Standards Institute. The first American national standard for electronic and automated sphygmomanometers was published in monograph form in 1987. The objective of the revised 1992 standard for electronic and automated sphygmomanometers is to provide updated labeling, safety, and performance requirements that help ensure that consumers and health care professionals are supplied with safe, accurate devices for the indirect measurement of blood pressure, including ambulatory blood pressure recorders. This standard permits validation of the automatic or electronic device by comparison with either direct, intra-arterial blood pressure measurements or the noninvasive cuff/stethoscope technique, based on Korotkoff sounds identified by individuals trained in auscultation. This summary report of the 1992 American national standard for automatic sphygmomanometers provides recommendations for the methods of comparison, statistical analysis of the data, presentation of the results, and criteria for acceptability. Users, researchers, and instrument designers should refer to the American national standard monograph for detailed requirements.

Mesh:

Year:  1993        PMID: 8458649     DOI: 10.1161/01.hyp.21.4.504

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  57 in total

1.  The effect of education plus access on perceived fruit and vegetable consumption in a rural African American community intervention.

Authors:  E K Barnidge; E A Baker; M Schootman; F Motton; M Sawicki; F Rose
Journal:  Health Educ Res       Date:  2015-09-02

2.  Relationship between blood pressure obtained from the upper arm with a cuff-type sphygmomanometer and central blood pressure measured with a catheter-tipped micromanometer.

Authors:  Nobuyuki Ohte; Tomoaki Saeki; Hiromichi Miyabe; Seichiro Sakata; Seiji Mukai; Junichiro Hayano; Kiyomi Niki; Motoaki Sugawara; Genjiro Kimura
Journal:  Heart Vessels       Date:  2007-11-26       Impact factor: 2.037

3.  Evaluation of pharmacy students' blood pressure and heart rate measurement skills after completion of a patient assessment course.

Authors:  Kenneth L McCall; Cynthia Raehl; Sherida Nelson; Krystal Haase; David S Fike
Journal:  Am J Pharm Educ       Date:  2007-02-15       Impact factor: 2.047

4.  Assessment of manual blood pressure and heart rate measurement skills of pharmacy students: a follow-up investigation.

Authors:  Katherine E Elliott; Kenneth L McCall; David S Fike; Jill Polk; Cynthia Raehl
Journal:  Am J Pharm Educ       Date:  2008-06-15       Impact factor: 2.047

5.  Adaptation of a Modified DASH Diet to a Rural African American Community Setting.

Authors:  Elizabeth A Baker; Ellen K Barnidge; Mario Schootman; Marjorie Sawicki; Freda L Motton-Kershaw
Journal:  Am J Prev Med       Date:  2016-09-12       Impact factor: 5.043

6.  Intensified monitoring of circadian blood pressure and heart rate before and after intravitreous injection of bevacizumab: preliminary findings of a pilot study.

Authors:  Focke Ziemssen; Qi Zhu; Swaantje Peters; Salvatore Grisanti; Mohammed El Wardani; Peter Szurman; Karl U Bartz-Schmidt; Tjalf Ziemssen
Journal:  Int Ophthalmol       Date:  2008-04-17       Impact factor: 2.031

7.  An alternative method of validating blood pressure measurement: the sphygmooscillographic method.

Authors:  A Sapinski
Journal:  J Clin Monit       Date:  1995-09

8.  Differential vascular reactivity responses acutely following ingestion of a nitrate rich red spinach extract.

Authors:  Cody T Haun; Wesley C Kephart; Angelia M Holland; Christopher B Mobley; Anna E McCloskey; Joshua J Shake; David D Pascoe; Michael D Roberts; Jeffrey S Martin
Journal:  Eur J Appl Physiol       Date:  2016-09-30       Impact factor: 3.078

9.  Influence of patient characteristics on success of ambulatory blood pressure monitoring.

Authors:  Michelle A Fravel; Michael E Ernst; Cynthia A Weber; Jeffrey D Dawson; Barry L Carter; George R Bergus
Journal:  Pharmacotherapy       Date:  2008-11       Impact factor: 4.705

10.  A new oscillometric method for pulse wave analysis: comparison with a common tonometric method.

Authors:  S Wassertheurer; J Kropf; T Weber; M van der Giet; J Baulmann; M Ammer; B Hametner; C C Mayer; B Eber; D Magometschnigg
Journal:  J Hum Hypertens       Date:  2010-03-18       Impact factor: 3.012

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.