Literature DB >> 29993523

Ballistocardiogram-Based Approach to Cuffless Blood Pressure Monitoring: Proof of Concept and Potential Challenges.

Chang-Sei Kim, Andrew M Carek, Omer T Inan, Ramakrishna Mukkamala, Jin-Oh Hahn.   

Abstract

OBJECTIVE: The goal was to propose and establish the proof of concept of an ultraconvenient cuffless blood pressure monitoring approach based on the ballistocardiogram.
METHODS: The proposed approach monitors blood pressure by exploiting two features in the whole-body head-to-foot ballistocardiogram measured using a force plate: the time interval between the first ("I") and second ("J") major waves ("I-J interval") for diastolic pressure and the amplitude between the J and third major ("K") waves ("J-K amplitude") for pulse pressure. The efficacy of the approach was examined in 22 young healthy volunteers by investigating the diastolic pressure monitoring performance of pulse transit time, pulse arrival time, and ballistocardiogram's I-J interval, and the systolic pressure monitoring performance of pulse transit time and I-J interval in conjunction with ballistocardiogram's J-K amplitude.
RESULTS: The I-J interval was comparable to pulse transit time and pulse arrival time in monitoring diastolic pressure, and the J-K amplitude could provide meaningful improvement to pulse transit time and I-J interval in monitoring systolic pressure.
CONCLUSION: The ballistocardiogram may contribute toward ultraconvenient and more accurate cuffless blood pressure monitoring. SIGNIFICANCE: The proposed approach has potential to complement the pulse transit time technique for cuffless blood pressure monitoring in two ways. First, it may be integrated with pulse transit time to enable independent monitoring of diastolic and systolic pressures via the J-K amplitude. Second, it may even enable diastolic and systolic pressure monitoring from the ballistocardiogram alone.

Entities:  

Mesh:

Year:  2018        PMID: 29993523      PMCID: PMC6230266          DOI: 10.1109/TBME.2018.2797239

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  25 in total

1.  Expert consensus document on arterial stiffness: methodological issues and clinical applications.

Authors:  Stephane Laurent; John Cockcroft; Luc Van Bortel; Pierre Boutouyrie; Cristina Giannattasio; Daniel Hayoz; Bruno Pannier; Charalambos Vlachopoulos; Ian Wilkinson; Harry Struijker-Boudier
Journal:  Eur Heart J       Date:  2006-09-25       Impact factor: 29.983

2.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure.

Authors:  Michela Masè; Walter Mattei; Roberta Cucino; Luca Faes; Giandomenico Nollo
Journal:  J Electrocardiol       Date:  2011 Mar-Apr       Impact factor: 1.438

3.  Systolic versus diastolic blood pressure and risk of coronary heart disease. The Framingham study.

Authors:  W B Kannel; T Gordon; M J Schwartz
Journal:  Am J Cardiol       Date:  1971-04       Impact factor: 2.778

4.  Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

Authors:  C C Young; J B Mark; W White; A DeBree; J S Vender; A Fleming
Journal:  J Clin Monit       Date:  1995-07

5.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios.

Authors:  G Drzewiecki; R Hood; H Apple
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

6.  The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise.

Authors:  G V Marie; C R Lo; J Van Jones; D W Johnston
Journal:  Psychophysiology       Date:  1984-09       Impact factor: 4.016

7.  Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement.

Authors:  Andrew M Carek; Omer T Inan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-05-23       Impact factor: 3.833

8.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

9.  Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time.

Authors:  Stephanie L-O Martin; Andrew M Carek; Chang-Sei Kim; Hazar Ashouri; Omer T Inan; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Sci Rep       Date:  2016-12-15       Impact factor: 4.379

10.  Ballistocardiogram: Mechanism and Potential for Unobtrusive Cardiovascular Health Monitoring.

Authors:  Chang-Sei Kim; Stephanie L Ober; M Sean McMurtry; Barry A Finegan; Omer T Inan; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2016-08-09       Impact factor: 4.379

View more
  11 in total

1.  Mitigation of Instrument-Dependent Variability in Ballistocardiogram Morphology: Case Study on Force Plate and Customized Weighing Scale.

Authors:  Yang Yao; Zahra Ghasemi; Md Mobashir Hasan Shandhi; Hazar Ashouri; Lisheng Xu; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE J Biomed Health Inform       Date:  2019-02-25       Impact factor: 5.772

2.  Efficient detection of aortic stenosis using morphological characteristics of cardiomechanical signals and heart rate variability parameters.

Authors:  Arash Shokouhmand; Nicole D Aranoff; Elissa Driggin; Philip Green; Negar Tavassolian
Journal:  Sci Rep       Date:  2021-12-10       Impact factor: 4.379

3.  A Survey of Challenges and Opportunities in Sensing and Analytics for Risk Factors of Cardiovascular Disorders.

Authors:  Nathan C Hurley; Erica S Spatz; Harlan M Krumholz; Roozbeh Jafari; Bobak J Mortazavi
Journal:  ACM Trans Comput Healthc       Date:  2020-12-30

4.  The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Mousavi; Chang-Sei Kim; Ramakrishna Mukkamala; Dae-Geun Jang; Byung-Hoon Ko; Jongwook Lee; Ui Kun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-07-23       Impact factor: 4.379

5.  Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Sadat Mousavi; Chang-Sei Kim; Barry Finegan; M Sean McMurtry; Ramakrishna Mukkamala; Dae-Geun Jang; Uikun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

Review 6.  Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices.

Authors:  Jaegeol Cho
Journal:  J Healthc Eng       Date:  2019-06-16       Impact factor: 2.682

7.  Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters.

Authors:  Charles Carlson; Vanessa-Rose Turpin; Ahmad Suliman; Carl Ade; Steve Warren; David E Thompson
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

8.  Pulse arrival time as a surrogate of blood pressure.

Authors:  Eoin Finnegan; Shaun Davidson; Mirae Harford; João Jorge; Peter Watkinson; Duncan Young; Lionel Tarassenko; Mauricio Villarroel
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

9.  Study on the effect of the ballistocardiography-based "Internet + Smart Bed" health management system on the quality of life of elderly users with chronic diseases.

Authors:  Xiuping Han; Kai Zhong; Jiadong Wang; Wenchao Pan; Hui Cao; Lingai Gao; Yang Gao; Jingze Zhu; Hongwen Li; Xiangdong Yang
Journal:  Ann Transl Med       Date:  2022-03

10.  Conventional pulse transit times as markers of blood pressure changes in humans.

Authors:  Robert C Block; Mohammad Yavarimanesh; Keerthana Natarajan; Andrew Carek; Azin Mousavi; Anand Chandrasekhar; Chang-Sei Kim; Junxi Zhu; Giovanni Schifitto; Lalit K Mestha; Omer T Inan; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Sci Rep       Date:  2020-10-02       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.