Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application.

P A Devane1, R B Bourne, C H Rorabeck, S MacDonald, E J Robinson.   

Abstract

The new 3-dimensional technique was applied to the radiographs of 141 patients who had received Porous Coated Anatomic total hip prostheses. Values were obtained for the position of the acetabular cup, the 3-dimensional distance and direction of femoral head displacement, and the minimum volume of polyethylene debris produced. Mean age of the patients at the time of replacement was 61 years old; mean followup was 5.6 years (range, 4-7.2 years). Change in the position of the femoral head between initial and long-term followup films was assumed to represent polyethylene wear, and formulas were used to calculate the minimal volume of polyethylene debris produced. The overall rate of 3-dimensional femoral head displacement was 0.264 mm per year, almost twice that usually quoted in the current literature for 2-dimensional linear wear. A significant contribution to this value was made by anterior and posterior displacement. Two-dimensional femoral head displacement (measured in the plane of anteroposterior radiographs) on the same patients was 0.149 mm per year. The mean minimum volume of polyethylene debris produced after 5.6 years was 0.448 cm3 (range, 0.00-2.83 cm3), giving a mean rate of 0.079 cm3 polyethylene debris produced each year. Thirteen patients in this series had radiologic osteolysis and a significantly greater femoral head displacement and polyethylene volumetric wear than those with no osteolysis. Patients with a 32-mm femoral head diameter and a polyethylene linear < 1 cm thick had a significantly greater amount of polyethylene wear. This series gives previously unavailable data on 3-dimensional femoral head displacement and is the first report that correlates the minimum volume of polyethylene wear produced with radiologic osteolysis.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7554645

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

2.  Eleven-year results of the ABG I hip replacement.

Authors:  W Y Kim; B N Muddu
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

3.  Has a patient type with peri-prosthetic femoral fractures evolved?

Authors:  Matthieu Ehlinger; David Bahlau; Michel Rahme; Philippe Adam; François Bonnomet
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

4.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

5.  Role of macrophages in the biological reaction to wear debris from joint replacements.

Authors:  Christophe Nich; Stuart B Goodman
Journal:  J Long Term Eff Med Implants       Date:  2014

Review 6.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

7.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

8.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

9.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

10.  [HPV-related oropharyngeal squamous cell carcinoma-Incidence steadily rising].

Authors:  M Suchan; N Wuerdemann; S J Sharma; J P Klussmann
Journal:  HNO       Date:  2021-06-18       Impact factor: 1.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.