Literature DB >> 18751806

Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Colin E Poole1, Shantanu S Patil, Darryl D D'Lima, Clifford W Colwell.   

Abstract

Modular acetabular systems have several advantages; however, increased polyethylene wear has been recognized as a disadvantage. In our study, an acetabular shell design with a highly polished inner surface, a locking mechanism that minimizes micromotion, and a high polyethylene liner to shell conformity was evaluated. A prospective cohort of 50 consecutive hips was followed up for a mean of 3.6 years (range, 2-7 years). One patient required an early revision for recurrent instability. Mean linear head penetration rates were 0.242 mm/year (range, 0.048-0.655 mm/year). The true linear wear rate was calculated after subtracting the linear wear in the first follow-up year from the total wear at the end of the follow-up. The true linear wear rate was 0.173 mm/year (range, 0.03-0.423 mm/year). A positive correlation was found between wear rate and male gender. The low head penetration rates suggest that a polished liner with an improved locking mechanism and increased liner conformity can reduce polyethylene wear.

Entities:  

Year:  2005        PMID: 18751806      PMCID: PMC2504131          DOI: 10.1007/s11420-005-0102-6

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  26 in total

1.  Motion at the modular acetabular shell and liner interface. A comparative study.

Authors:  T K Fehring; S E Smith; E R Braun; C Mobley; P L Wang; W L Griffin
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

2.  The influence of weight-bearing on the measurement of polyethylene wear in THA.

Authors:  P N Smith; R S Ling; R Taylor
Journal:  J Bone Joint Surg Br       Date:  1999-03

3.  The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty.

Authors:  K D Moore; R L Barrack; C J Sychterz; J Sawhney; A M Yang; C A Engh
Journal:  J Bone Joint Surg Am       Date:  2000-01       Impact factor: 5.284

4.  Polyethylene liner dissociation in Harris-Galante acetabular components: a report of 7 cases.

Authors:  Jason Werle; Stuart Goodman; David Schurman; John Lannin
Journal:  J Arthroplasty       Date:  2002-01       Impact factor: 4.757

5.  Triple osteotomy of the pelvis for acetabular dysplasia: results at 8 to 15 years.

Authors:  M de Kleuver; M A Kooijman; P W Pavlov; R P Veth
Journal:  J Bone Joint Surg Br       Date:  1997-03

6.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

7.  Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components. A report of eighteen cases.

Authors:  A González della Valle; P S Ruzo; S Li; P Pellicci; T P Sculco; E A Salvati
Journal:  J Bone Joint Surg Am       Date:  2001-04       Impact factor: 5.284

8.  Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty.

Authors:  Anthony M Young; Christi J Sychterz; Robert H Hopper; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

9.  Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests; the influence of counterface roughness.

Authors:  J L Hailey; E Ingham; M Stone; B M Wroblewski; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

10.  Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application.

Authors:  P A Devane; R B Bourne; C H Rorabeck; S MacDonald; E J Robinson
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

View more
  1 in total

1.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.