Literature DB >> 7377362

Indirect mean arterial pressure in the anesthetized dog.

L A Geddes, W Combs, W Denton, S J Whistler, J D Bourland.   

Abstract

Using the oscillometric method, indirect mean arterial pressure was measured in 14 pentobarbital-anesthetized dogs (8-24 kg) with mean arterial pressure ranging from 23 to 160 mmHg. The effect of cuff size, in relation to forelimb circumference was investigated. Indirect mean arterial pressure agreed with direct mean arterial pressure when the cuff width was about 40% of the forelimb circumference.

Entities:  

Mesh:

Year:  1980        PMID: 7377362     DOI: 10.1152/ajpheart.1980.238.5.H664

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  15 in total

1.  Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs.

Authors:  Paul D MacFarlane; Nicola Grint; Alexandra Dugdale
Journal:  Vet Res Commun       Date:  2010-03-23       Impact factor: 2.459

2.  Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs.

Authors:  Christopher E Haberman; Chang W Kang; Jefferson D Morgan; Scott A Brown
Journal:  Can J Vet Res       Date:  2006-07       Impact factor: 1.310

3.  Vibration technique for indirect measurement of diastolic arterial pressure in human fingers.

Authors:  H Shimazu; H Ito; A Kawarada; H Kobayashi; A Hiraiwa; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

Review 4.  How to Measure 24-hour Central Blood Pressure and Its Potential Clinical Implications.

Authors:  Giacomo Pucci; Francesca Battista; Alessandra Crocetti; Giovanni Tilocca; Enrico Boschetti
Journal:  High Blood Press Cardiovasc Prev       Date:  2017-04-10

5.  Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

Authors:  Turi K Aarnes; John A E Hubbell; Phillip Lerche; Richard M Bednarski
Journal:  Can Vet J       Date:  2012-08       Impact factor: 1.008

6.  Idea to measure diastolic arterial pressure by volume oscillometric method in human fingers.

Authors:  H Shimazu; H Ito; H Kobayashi; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1986-09       Impact factor: 2.602

Review 7.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

8.  The anesthetic interaction of propofol and sevoflurane on the minimum alveolar concentration preventing motor movement (MACNM) in dogs.

Authors:  Jill Singsank-Coats; Reza Seddighi; Barton W Rohrbach; Sherry K Cox; Christine M Egger; Thomas J Doherty
Journal:  Can J Vet Res       Date:  2015-04       Impact factor: 1.310

Review 9.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

10.  Comparison of direct and indirect blood pressure measurements in anesthetized dogs.

Authors:  M J Gains; K M Grodecki; R M Jacobs; D Dyson; R A Foster
Journal:  Can J Vet Res       Date:  1995-07       Impact factor: 1.310

View more