Literature DB >> 2601431

Vibration technique for indirect measurement of diastolic arterial pressure in human fingers.

H Shimazu, H Ito, A Kawarada, H Kobayashi, A Hiraiwa, K Yamakoshi.   

Abstract

Diastolic pressure Pd was indirectly measured by vibrating a finger artery with a 10 Hz sinusoidal pressure variation during a gradual increase (or decrease) in occlusive cuff pressure Pc. Pulsatile arterial volume changes on which sinusoidal variations are superimposed were detected by a transmitted infra-red photoelectric plethysmograph (TIPP). It is known that volume change in an artery shows a maximum amplitude at the transmural pressure Pt level equal to 0 mm Hg due to the nonlinear viscoelastic properties of the arterial wall. For the same reason, the amplitude of the sinusoidal volume variation reached its maximum at the end-diastolic phase, when Pc was controlled to be exactly equal to Pd. The indirect Pd values determined from Pc were compared with those simultaneously measured by a direct method in rabbit forelegs and by the volume-compensation method in human fingers. Using the principle of the volume oscillometric method systolic and mean pressures were also determined by this system.

Entities:  

Mesh:

Year:  1989        PMID: 2601431     DOI: 10.1007/bf02446221

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  Noninvasive measurement of the volume elastic modulus in finger arteries using photoelectric plethysmography.

Authors:  H Shimazu; K Yamakoshi; A Kamiya
Journal:  IEEE Trans Biomed Eng       Date:  1986-08       Impact factor: 4.538

Review 2.  Analysis of pulsatile blood flow.

Authors:  E O Attinger
Journal:  Adv Biomed Eng Med Phys       Date:  1968

3.  Idea to measure diastolic arterial pressure by volume oscillometric method in human fingers.

Authors:  H Shimazu; H Ito; H Kobayashi; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1986-09       Impact factor: 2.602

4.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

5.  New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study.

Authors:  K Yamakoshi; H Shimazu; M Shibata; A Kamiya
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

6.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

7.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.

Authors:  G W Mauck; C R Smith; L A Geddes; J D Bourland
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

8.  Indirect measurement of mean blood pressure in the normotensive and hypotensive horse.

Authors:  H Latshaw; J F Fessler; S J Whistler; L A Geddes
Journal:  Equine Vet J       Date:  1979-07       Impact factor: 2.888

9.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11

10.  Indirect mean arterial pressure in the anesthetized dog.

Authors:  L A Geddes; W Combs; W Denton; S J Whistler; J D Bourland
Journal:  Am J Physiol       Date:  1980-05
View more
  4 in total

1.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion.

Authors:  R Raamat; J Talts; K Jagomägi; E Länsimies
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure.

Authors:  P D Baker; D R Westenskow; K Kück
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

3.  Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries.

Authors:  J Penaz; N Honzikova; P Jurak
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

Review 4.  A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform.

Authors:  Tasbiraha Athaya; Sunwoong Choi
Journal:  Sensors (Basel)       Date:  2022-05-23       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.