Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs.

Paul D MacFarlane1, Nicola Grint, Alexandra Dugdale.   

Abstract

Monitoring blood pressure during anaesthesia is widely recommended in man and animals. The accuracy of any device used to measure blood pressure is an important consideration when selecting monitoring equipment, the ANSI/AAMI SP10 standard is widely cited in this respect in recent veterinary publications. Blood pressure was monitored using invasive and non-invasive techniques during clinical anaesthesia in 19 dogs. The results were compared using Bland-Altman analysis. The bias (and limits of agreement) between invasive and non-invasive measurement was 7.1 mmHg (+/-34.7) for systolic blood pressure, -1.8 mmHg (+/-27.4) for mean blood pressure and 6.9 mmHg (+/-27.5) for diastolic blood pressure. In a clinical setting the bias between invasive and non-invasive measurement techniques was similar or smaller than laboratory reports, however the limits of agreement were considerably wider suggesting that care should be exercised when interpreting NIBP values.

Entities:  

Mesh:

Year:  2010        PMID: 20306347     DOI: 10.1007/s11259-010-9346-9

Source DB:  PubMed          Journal:  Vet Res Commun        ISSN: 0165-7380            Impact factor:   2.459


  21 in total

1.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

2.  Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults.

Authors:  Eoin O'Brien; Thomas Pickering; Roland Asmar; Martin Myers; Gianfranco Parati; Jan Staessen; Thomas Mengden; Yutaka Imai; Bernard Waeber; Paolo Palatini; William Gerin
Journal:  Blood Press Monit       Date:  2002-02       Impact factor: 1.444

3.  Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats.

Authors:  Karen M Pedersen; Michael A Butler; Annette K Ersbøll; Henrik D Pedersen
Journal:  J Am Vet Med Assoc       Date:  2002-09-01       Impact factor: 1.936

4.  Accuracy of an oscillometric blood pressure monitor during phenylephrine-induced hypertension in dogs.

Authors:  Rose M McMurphy; Melissa R Stoll; Raymond McCubrey
Journal:  Am J Vet Res       Date:  2006-09       Impact factor: 1.156

5.  Results of the confidential enquiry into perioperative small animal fatalities regarding risk factors for anesthetic-related death in dogs.

Authors:  David C Brodbelt; Dirk U Pfeiffer; Lesley E Young; James L N Wood
Journal:  J Am Vet Med Assoc       Date:  2008-10-01       Impact factor: 1.936

Review 6.  Arterial blood pressure monitoring in anesthetized animals.

Authors:  A E Wagner; D C Brodbelt
Journal:  J Am Vet Med Assoc       Date:  1997-05-01       Impact factor: 1.936

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems.

Authors:  E O'Brien; J Petrie; W Littler; M de Swiet; P L Padfield; K O'Malley; M Jamieson; D Altman; M Bland; N Atkins
Journal:  J Hypertens       Date:  1990-07       Impact factor: 4.844

9.  Comparison of direct and indirect blood pressure measurements in anesthetized dogs.

Authors:  M J Gains; K M Grodecki; R M Jacobs; D Dyson; R A Foster
Journal:  Can J Vet Res       Date:  1995-07       Impact factor: 1.310

10.  Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs.

Authors:  Catherine J A Deflandre; Ludo J Hellebrekers
Journal:  Vet Anaesth Analg       Date:  2007-08-13       Impact factor: 1.648

View more
  3 in total

1.  Comparison of telemetry and high-definition oscillometry for blood pressure measurements in conscious dogs: effects of torcetrapib.

Authors:  Olivier Meyer; Roland Jenni; Andrea Greiter-Wilke; Alexander Breidenbach; Henry H Holzgrefe
Journal:  J Am Assoc Lab Anim Sci       Date:  2010-07       Impact factor: 1.232

Review 2.  Optimal management of the critically ill: anaesthesia, monitoring, data capture, and point-of-care technological practices in ovine models of critical care.

Authors:  Saul Chemonges; Kiran Shekar; John-Paul Tung; Kimble R Dunster; Sara Diab; David Platts; Ryan P Watts; Shaun D Gregory; Samuel Foley; Gabriela Simonova; Charles McDonald; Rylan Hayes; Judith Bellpart; Daniel Timms; Michelle Chew; Yoke L Fung; Michael Toon; Marc O Maybauer; John F Fraser
Journal:  Biomed Res Int       Date:  2014-03-25       Impact factor: 3.411

3.  Branham sign in dogs undergoing interventional patent ductus arteriosus occlusion or surgical ligation: A retrospective study.

Authors:  Filipe L Madruga; Yolanda Martinez Pereira; Ambra Panti; Ian Handel; Geoff Culshaw
Journal:  Open Vet J       Date:  2021-11-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.