Literature DB >> 23372197

Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

Turi K Aarnes1, John A E Hubbell, Phillip Lerche, Richard M Bednarski.   

Abstract

This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was -9.9 ± 21.9 mmHg with a range of -76 to 54 mmHg, and the 95% limits of agreement (LOA) were -33 to 53 mmHg. The difference between DABP measurements was -1.8 ± 15.6 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -32 to 29 mmHg. The difference between MABP measurements was -2.9 ± 17.0 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method.

Entities:  

Mesh:

Year:  2012        PMID: 23372197      PMCID: PMC3398528     

Source DB:  PubMed          Journal:  Can Vet J        ISSN: 0008-5286            Impact factor:   1.008


  29 in total

1.  Cardiopulmonary effects of sevoflurane, compared with halothane, enflurane, and isoflurane, in dogs.

Authors:  T Mutoh; R Nishimura; H Y Kim; S Matsunaga; N Sasaki
Journal:  Am J Vet Res       Date:  1997-08       Impact factor: 1.156

2.  Comparison of direct and indirect blood pressure measurement in anesthetized dogs.

Authors:  D C Sawyer; M Brown; E L Striler; R A Durham; M A Langham; R H Rech
Journal:  Lab Anim Sci       Date:  1991-04

Review 3.  Arterial blood pressure monitoring in anesthetized animals.

Authors:  A E Wagner; D C Brodbelt
Journal:  J Am Vet Med Assoc       Date:  1997-05-01       Impact factor: 1.936

4.  Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs.

Authors:  Ann P Bosiack; F A Mann; John R Dodam; Colette C Wagner-Mann; Keith R Branson
Journal:  J Vet Emerg Crit Care (San Antonio)       Date:  2010-04-01

5.  Indirect blood pressure measurement in anaesthetised animals.

Authors:  J B Glen
Journal:  Vet Rec       Date:  1970-09-19       Impact factor: 2.695

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Indirect mean arterial pressure in the anesthetized dog.

Authors:  L A Geddes; W Combs; W Denton; S J Whistler; J D Bourland
Journal:  Am J Physiol       Date:  1980-05

Review 8.  Llama anesthetic programs.

Authors:  R B Heath
Journal:  Vet Clin North Am Food Anim Pract       Date:  1989-03       Impact factor: 3.357

Review 9.  Anesthesia in the llama.

Authors:  T W Riebold; A J Kaneps; W B Schmotzer
Journal:  Vet Surg       Date:  1989 Sep-Oct       Impact factor: 1.495

10.  Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes.

Authors:  Sathya K Chinnadurai; Amy Wrenn; Ryan S DeVoe
Journal:  J Am Vet Med Assoc       Date:  2009-03-01       Impact factor: 1.936

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.