Literature DB >> 32255821

Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Alicia Skelding1, Alexander Valverde1.   

Abstract

Arterial blood pressure is a common parameter evaluated in conscious and anesthetized veterinary species. Non-invasive blood pressure measurement techniques, such as Doppler ultrasonic flow detector and oscillometry, are attractive in certain animals due to their availability and ease of use. The greatest limitation to non-invasive blood pressure monitoring can be its inaccuracy, particularly in hypotensive or hypertensive patients and in certain species. Part 1 of this 2-part review summarizes the current techniques available to non-invasively measure arterial blood pressure in animals and discusses validation of non-invasive devices. Part 2 summarizes the veterinary literature that evaluates the use of non-invasive blood pressure measurement techniques in conscious and anesthetized species and develops general conclusions for proper use and interpretation of data from non-invasive blood pressure devices. Copyright and/or publishing rights held by the Canadian Veterinary Medical Association.

Entities:  

Year:  2020        PMID: 32255821      PMCID: PMC7074114     

Source DB:  PubMed          Journal:  Can Vet J        ISSN: 0008-5286            Impact factor:   1.008


  42 in total

1.  Inter- and intraindividual variation in Doppler ultrasonic indirect blood pressure measurements in healthy cats.

Authors:  A H Sparkes; S M Caney; M C King; T J Gruffydd-Jones
Journal:  J Vet Intern Med       Date:  1999 Jul-Aug       Impact factor: 3.333

2.  Evaluation of the white-coat effect in cats.

Authors:  A M Belew; T Barlett; S A Brown
Journal:  J Vet Intern Med       Date:  1999 Mar-Apr       Impact factor: 3.333

3.  Accuracy of indirect measurement of blood pressure in neonatal foals.

Authors:  Steeve Giguère; Harvey A Knowles; Alexander Valverde; Eric Bucki; Linda Young
Journal:  J Vet Intern Med       Date:  2005 Jul-Aug       Impact factor: 3.333

4.  Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.

Authors:  S Brown; C Atkins; R Bagley; A Carr; L Cowgill; M Davidson; B Egner; J Elliott; R Henik; M Labato; M Littman; D Polzin; L Ross; P Snyder; R Stepien
Journal:  J Vet Intern Med       Date:  2007 May-Jun       Impact factor: 3.333

5.  Issues and pitfalls in method comparison studies.

Authors:  Sonja Hartnack
Journal:  Vet Anaesth Analg       Date:  2014-02-27       Impact factor: 1.648

6.  Indirect measurment of arterial blood pressure by Doppler ultrasonic sphygmomanometry.

Authors:  H F Stegall; M B Kardon; W T Kemmerer
Journal:  J Appl Physiol       Date:  1968-12       Impact factor: 3.531

7.  Hemodynamic effects of sevoflurane in cats.

Authors:  Bruno H Pypendop; Jan E Ilkiw
Journal:  Am J Vet Res       Date:  2004-01       Impact factor: 1.156

8.  A comparison of indirect blood pressure monitoring techniques in the anesthetized cat.

Authors:  N A Caulkett; S L Cantwell; D M Houston
Journal:  Vet Surg       Date:  1998 Jul-Aug       Impact factor: 1.495

9.  Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes.

Authors:  Sathya K Chinnadurai; Amy Wrenn; Ryan S DeVoe
Journal:  J Am Vet Med Assoc       Date:  2009-03-01       Impact factor: 1.936

10.  RBC motion and the basis of ultrasound Doppler instrumentation.

Authors:  Talat Uppal; Ritu Mogra
Journal:  Australas J Ultrasound Med       Date:  2015-12-31
View more
  2 in total

1.  Agreement of High-Definition Oscillometry (HDO) and Invasive Blood Pressure Measurements at a Metatarsal Artery in Isoflurane-Anaesthetised Horses.

Authors:  Lara Twele; Stephan Neudeck; Julien Delarocque; Nicole Verhaar; Julia Reiners; Mike Noll; Julia Tünsmeyer; Sabine B R Kästner
Journal:  Animals (Basel)       Date:  2022-02-02       Impact factor: 2.752

2.  'The Mercury Challenge': feline systolic blood pressure in primary care practice - a European survey.

Authors:  Andrew Sparkes; Catherine Garelli-Paar; Thomas Blondel; Emilie Guillot
Journal:  J Feline Med Surg       Date:  2022-06-27       Impact factor: 1.971

  2 in total