Literature DB >> 12835959

Radiation exposure of multi-row detector spiral computed tomography of the pulmonary arteries: comparison with digital subtraction pulmonary angiography.

Jan W Kuiper1, Jacob Geleijns, Niels A A Matheijssen, Wouter Teeuwisse, Peter M T Pattynama.   

Abstract

The purpose of this study was to determine and compare the effective dose of multidetector computed tomographic angiography (MDCT) and digital subtraction angiography (DSA) studies for diagnosing a pulmonary embolus (PE). Radiation exposure was measured as computed tomography dose index (MDCT) or as dose-area product (DSA) and was subsequently expressed in the quantity effective dose. Effective doses were obtained in 27 patients who underwent MDCT and in 12 patients who underwent DSA for suspected PE. The MDCT angiography was performed on a Siemens Volume Zoom CT scanner and DSA on a Philips Integris V-3000 system according to standardized protocols. Average effective dose for MDCT angiography of the pulmonary arteries (27 patients) was 4.2 mSv (range 2.2-6.0 mSv). Pulmonary DSA gained an average effective dose (12 patients) of 7.1 mSv (range 3.3-17.3 mSv). Our results show that the effective doses in MDCT angiography studies for PE are moderate and even slightly lower in comparison with pulmonary DSA in a comparable patient group. Variations in patient dose are smaller for MDCT, probably because this procedure can be more strictly protocolized. Patient dose should not be restrictive in the discussion of CTA replacing DSA for diagnosing PE.

Entities:  

Mesh:

Year:  2002        PMID: 12835959     DOI: 10.1007/s00330-002-1753-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  11 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Clinical value of thin collimation in the diagnostic workup of pulmonary embolism.

Authors:  M Remy-Jardin; J Remy; F Baghaie; M Fribourg; D Artaud; A Duhamel
Journal:  AJR Am J Roentgenol       Date:  2000-08       Impact factor: 3.959

3.  Sensitivity and specificity of helical computed tomography in the diagnosis of pulmonary embolism: a systematic review.

Authors:  S W Rathbun; G E Raskob; T L Whitsett
Journal:  Ann Intern Med       Date:  2000-02-01       Impact factor: 25.391

4.  Pulmonary embolism: validation of spiral CT angiography in 149 patients.

Authors:  A B van Rossum; P M Pattynama; E R Ton; F E Treurniet; J W Arndt; B van Eck; G J Kieft
Journal:  Radiology       Date:  1996-11       Impact factor: 11.105

5.  An evaluation of the Diamentor transmission ionisation chamber in indicating exposure-area product (R cm2) during diagnostic radiological examinations.

Authors:  P C Shrimpton; B F Wall
Journal:  Phys Med Biol       Date:  1982-06       Impact factor: 3.609

6.  A method for describing the doses delivered by transmission x-ray computed tomography.

Authors:  T B Shope; R M Gagne; G C Johnson
Journal:  Med Phys       Date:  1981 Jul-Aug       Impact factor: 4.071

7.  A rational approach to dose reduction in CT: individualized scan protocols.

Authors:  J E Wilting; A Zwartkruis; M S van Leeuwen; J Timmer; A G Kamphuis; M Feldberg
Journal:  Eur Radiol       Date:  2001-07-26       Impact factor: 5.315

8.  Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis?

Authors:  B Ghaye; D Szapiro; I Mastora; V Delannoy; A Duhamel; J Remy; M Remy-Jardin
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

9.  Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy.

Authors:  M Remy-Jardin; J Remy; F Deschildre; D Artaud; J P Beregi; C Hossein-Foucher; X Marchandise; A Duhamel
Journal:  Radiology       Date:  1996-09       Impact factor: 11.105

10.  Can helical CT replace scintigraphy in the diagnostic process in suspected pulmonary embolism? A retrolective-prolective cohort study focusing on total diagnostic yield.

Authors:  A B van Rossum; P M Pattynama; W M Mallens; J Hermans; H G Heijerman
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

View more
  10 in total

1.  Radiation dose in helical CT for detection of pulmonary embolism.

Authors:  S Diederich
Journal:  Eur Radiol       Date:  2003-07       Impact factor: 5.315

2.  Relationship between encephalopathy and portal vein-vena cava shunt: value of computed tomography during arterial portography.

Authors:  Qian Chu; Zhen Li; Su-Ming Zhang; Dao-Yu Hu; Ming Xiao
Journal:  World J Gastroenterol       Date:  2004-07-01       Impact factor: 5.742

3.  Diagnostic value of 16 slices spiral-CT for portal vein disorders.

Authors:  Zhen Li; Daoyu Hu; Ming Xiao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2004

4.  Outcomes of negative multidetector computed tomography with pulmonary angiography in pregnant women suspected of pulmonary embolism.

Authors:  Ghada Bourjeily; Hanan Khalil; Christina Raker; Susan Martin; Pauline Auger; Michel Chalhoub; Lucia Larson; Margaret Miller
Journal:  Lung       Date:  2011-10-18       Impact factor: 2.584

5.  ACCF/AHA 2007 Clinical Competence Statement on vascular imaging with computed tomography and magnetic resonance.

Authors:  Christopher M Kramer; Matthew J Budoff; Zahi A Fayad; Victor A Ferrari; Corey Goldman; John R Lesser; Edward T Martin; Sanjay Rajagopalan; John P Reilly; George P Rodgers; Lawrence Wechsler
Journal:  Vasc Med       Date:  2007-11       Impact factor: 3.239

Review 6.  CT imaging in acute pulmonary embolism: diagnostic strategies.

Authors:  Joachim E Wildberger; Andreas H Mahnken; Marco Das; Axel Küttner; Michael Lell; Rolf W Günther
Journal:  Eur Radiol       Date:  2005-01-21       Impact factor: 5.315

Review 7.  Three-dimensional CT scanning: a new diagnostic modality in congenital heart disease.

Authors:  Phalla Ou; David S Celermajer; Giulio Calcagni; Francis Brunelle; Damien Bonnet; Daniel Sidi
Journal:  Heart       Date:  2006-09-04       Impact factor: 5.994

8.  Reduced z-axis technique for CT Pulmonary angiography in pregnancy--validation for practical use and dose reduction.

Authors:  Kaushik Shahir; Jonathan M McCrea; Luis Antonio Sosa Lozano; Lawrence R Goodman
Journal:  Emerg Radiol       Date:  2015-08-25

9.  Reduced Z-axis coverage multidetector CT angiography for suspected acute pulmonary embolism could decrease dose and maintain diagnostic accuracy.

Authors:  Joshua A Kallen; Bret F Coughlin; Michael T O'Loughlin; Barry Stein
Journal:  Emerg Radiol       Date:  2009-05-26

10.  Computed Tomography Angiography in Patients Evaluated for Acute Pulmonary Embolism with Low Serum D-dimer Levels: A Prospective Study.

Authors:  Lana Hirai Gimber; R Ing Travis; Jayme M Takahashi; Torrey L Goodman; Hyo-Chun Yoon
Journal:  Perm J       Date:  2009
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.