Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography.

Thomas C Gerber1, Ronald S Kuzo, Richard L Morin.   

Abstract

With increasing clinical use of cardiac CT imaging it is important that all health care providers referring for or administering such examinations are familiar with the concepts and values of radiation dosimetry in CT as well as with the basic principles of radiation protection. There are important technical differences pertinent to radiation dose between the CT scanner types that are currently being used for imaging of the heart and coronary arteries. As a result of these differences, the radiation dose typically is higher when a cardiac examination is performed with multidetector-row CT (MDCT) than when it is performed with electron beam CT. Several techniques have been described to reduce radiation dose of MDCT imaging by varying the X-ray tube current during a CT examination. The volume computed tomographic dose index (CTDIvol), the dose length product (DLP), and the effective dose (E) are the most useful parameters to describe and compare radiation doses received from cardiac CT examinations. When comparing radiation doses between scanning protocols and scanner types, the degree of image noise must be considered. Diagnostic, rather than aesthetic, quality of images should be the most important factor guiding the development of scanning protocols for cardiac CT imaging. Cardiac CT examinations should be ordered only by qualified health care providers, and the ordering clinicians should be aware of their responsibility of weighing risks of the radiation exposure against the expected benefits.

Mesh:

Year:  2005        PMID: 15915949     DOI: 10.1007/s10554-004-5338-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  22 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Performance evaluation of a multi-slice CT system.

Authors:  C H McCollough; F E Zink
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

Review 3.  Radiation dose in computed tomography of the heart.

Authors:  Richard L Morin; Thomas C Gerber; Cynthia H McCollough
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

4.  Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

Authors:  Amy Berrington de González; Sarah Darby
Journal:  Lancet       Date:  2004-01-31       Impact factor: 79.321

5.  Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation.

Authors:  Thomas C Gerber; Brian P Stratmann; Ronald S Kuzo; Birgit Kantor; Richard L Morin
Journal:  Invest Radiol       Date:  2005-08       Impact factor: 6.016

6.  Evaluation of the MDH Industries, Inc. pencil chamber for direct beam CT measurements.

Authors:  W Pavlicek; J Horton; R Turco
Journal:  Health Phys       Date:  1979-12       Impact factor: 1.316

7.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

8.  A method for describing the doses delivered by transmission x-ray computed tomography.

Authors:  T B Shope; R M Gagne; G C Johnson
Journal:  Med Phys       Date:  1981 Jul-Aug       Impact factor: 4.071

9.  Patient dose in cardiac computed tomography.

Authors:  Cynthia H McCollough
Journal:  Herz       Date:  2003-02       Impact factor: 1.443

10.  Imaging of congenital coronary anomalies with multislice computed tomography.

Authors:  Andrew R Deibler; Ronald S Kuzo; Matthias Vöhringer; E Eugene Page; Robert E Safford; J Norman Patron; Gary E Lane; Richard L Morin; Thomas C Gerber
Journal:  Mayo Clin Proc       Date:  2004-08       Impact factor: 7.616

View more
  29 in total

1.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

2.  Low dose dual-source CT angiography of the thoracic aorta.

Authors:  Cormac Farrelly; Amir Davarpanah; Aoife N Keeling; John Sheehan; Ann Ragin; Vahid Yaghmai; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-03       Impact factor: 2.357

Review 3.  Multidetector computed tomographic angiography of the cardiovascular system.

Authors:  Joshua Burrill; Zaid Dabbagh; Frank Gollub; Mohamed Hamady
Journal:  Postgrad Med J       Date:  2007-11       Impact factor: 2.401

4.  Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI.

Authors:  Pieter A van der Vleuten; Gonda J de Jonge; Daniël D Lubbers; René A Tio; Tineke P Willems; Matthijs Oudkerk; Felix Zijlstra
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

5.  The 'what, when, where, who and how?' of cardiac computed tomography in 2009: guidelines for the clinician.

Authors:  B J W Chow; E Larose; S Bilodeau; M L Ellins; P Galiwango; M Kass; T Sheth; D S Jassal; I D C Kirkpatrick; G B John Mancini; J Mayo; A Abraham; J White
Journal:  Can J Cardiol       Date:  2009-03       Impact factor: 5.223

6.  Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose.

Authors:  Sebastian Leschka; Paul Stolzmann; Florian T Schmid; Hans Scheffel; Bjoern Stinn; Borut Marincek; Hatem Alkadhi; Simon Wildermuth
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

7.  The associated factors for radiation dose variation in cardiac CT angiography.

Authors:  Ali B Alhailiy; Ernest U Ekpo; Peter L Kench; Elaine A Ryan; Patrick C Brennan; Mark McEntee
Journal:  Br J Radiol       Date:  2019-01-31       Impact factor: 3.039

8.  In vivo vibroacoustography of large peripheral arteries.

Authors:  Cristina Pislaru; Birgit Kantor; Randall R Kinnick; Jill L Anderson; Marie-Christine Aubry; Matthew W Urban; Mostafa Fatemi; James F Greenleaf
Journal:  Invest Radiol       Date:  2008-04       Impact factor: 6.016

9.  Airway wall geometry in asthma and nonasthmatic eosinophilic bronchitis.

Authors:  S Siddiqui; S Gupta; G Cruse; P Haldar; J Entwisle; S Mcdonald; P J Whithers; S V Hainsworth; H O Coxson; C Brightling
Journal:  Allergy       Date:  2009-02-11       Impact factor: 13.146

Review 10.  Routine quality control of clinical nuclear medicine instrumentation: a brief review.

Authors:  Pat Zanzonico
Journal:  J Nucl Med       Date:  2008-07       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.