Literature DB >> 7109726

New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: model experiment.

K Yamakoshi, H Shimazu, M Shibata, A Kamiya.   

Abstract

Entities:  

Mesh:

Year:  1982        PMID: 7109726     DOI: 10.1007/BF02442797

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  15 in total

1.  Arterial wall mechanics and composition and the effects of smooth muscle activation.

Authors:  R H Cox
Journal:  Am J Physiol       Date:  1975-09

2.  Measurement of blood content and arterial pressure in the human ear.

Authors:  E H WOOD; J R B KNUTSON; B E TAYLOR
Journal:  Proc Staff Meet Mayo Clin       Date:  1950-07-05

Review 3.  Mechanical properties of arteries

Authors:  P B Dobrin
Journal:  Physiol Rev       Date:  1978-04       Impact factor: 37.312

4.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1.

Authors:  J A Posey; L A Geddes; H Williams; A G Moore
Journal:  Cardiovasc Res Cent Bull       Date:  1969 Jul-Sep

5.  Mechanics of distension of dog veins and other very thin-walled tubular structures.

Authors:  A H Moreno; A I Katz; L D Gold; R V Reddy
Journal:  Circ Res       Date:  1970-12       Impact factor: 17.367

6.  New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study.

Authors:  K Yamakoshi; H Shimazu; M Shibata; A Kamiya
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

7.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

8.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.

Authors:  G W Mauck; C R Smith; L A Geddes; J D Bourland
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

9.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11

10.  Indirect mean arterial pressure in the anesthetized dog.

Authors:  L A Geddes; W Combs; W Denton; S J Whistler; J D Bourland
Journal:  Am J Physiol       Date:  1980-05
View more
  28 in total

1.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion.

Authors:  R Raamat; J Talts; K Jagomägi; E Länsimies
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

3.  Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

4.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

Authors:  H Shimazu; A Kawarada; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

5.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure.

Authors:  P D Baker; D R Westenskow; K Kück
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

6.  Development of noninvasive measurement of peripheral circulation and its medical application.

Authors:  H Nakamura
Journal:  Environ Health Prev Med       Date:  1997-04       Impact factor: 3.674

7.  Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method.

Authors:  S Tanaka; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

8.  Vibration technique for indirect measurement of diastolic arterial pressure in human fingers.

Authors:  H Shimazu; H Ito; A Kawarada; H Kobayashi; A Hiraiwa; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

9.  Noninvasive measurement of arterial elasticity in various human limbs.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

10.  Noninvasive method for estimating the mean capillary pressure and pre- and postcapillary resistance ratio in human fingers.

Authors:  H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1986-11       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.