Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method.

A Kawarada1, H Shimazu, H Ito, K Yamakoshi.   

Abstract

Using a volume-compensation technique, a portable device has been designed for the indirect measurement of beat-to-beat arterial pressure and its waveforms in the basal phalanx of fingers of ambulatory subjects. The device consists of (1) a transmission infra-red photoelectric plethysmograph (TIPP) to detect the variation of arterial volume, (2) a pneumatic cuff with an actuator, (3) a servosystem to control the cuff pressure, and (4) a stereo cassette tape recorder. Arterial pressure was determined from the cuff pressure which was controlled by the servosystem so as to maintain the arterial volume constant at the 'vascular unloading' state. This device is equipped with a compensator for any hydrostatic pressure difference between the heart and finger. Thus, the blood pressure at heart level can be obtained for any finger height. The total weight of the device was 1.6 kg. Blood pressure changes during walking, jogging, jumping, and exercises such as side-stepping, Master's two-step test and car driving, have been successfully recorded.

Entities:  

Mesh:

Year:  1991        PMID: 2016921     DOI: 10.1007/bf02446296

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  Portable blood pressure recorder. Accuracy and preliminary use in evaluating intradaily variations in pressure.

Authors:  A T HINMAN; B T ENGEL; A F BICKFORD
Journal:  Am Heart J       Date:  1962-05       Impact factor: 4.749

2.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1.

Authors:  J A Posey; L A Geddes; H Williams; A G Moore
Journal:  Cardiovasc Res Cent Bull       Date:  1969 Jul-Sep

3.  Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique.

Authors:  K Yamakoshi; A Kamiya; H Shimazu; H Ito; T Togawa
Journal:  Med Biol Eng Comput       Date:  1983-09       Impact factor: 2.602

4.  New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: model experiment.

Authors:  K Yamakoshi; H Shimazu; M Shibata; A Kamiya
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

5.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

6.  Ambulatory blood pressure monitoring: recent advances and clinical applications.

Authors:  M J Horan; N E Padgett; H L Kennedy
Journal:  Am Heart J       Date:  1981-06       Impact factor: 4.749

7.  Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres).

Authors:  J C Dorlas; J A Nijboer; W T Butijn; G M van der Hoeven; J J Settels; K H Wesseling
Journal:  Anesthesiology       Date:  1985-03       Impact factor: 7.892

8.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11
  8 in total
  4 in total

1.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

2.  Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method.

Authors:  S Tanaka; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

3.  Microprocessor-based physiological signal monitoring and recording system for ambulatory subjects.

Authors:  S D Kao; G J Jan
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

Review 4.  A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform.

Authors:  Tasbiraha Athaya; Sunwoong Choi
Journal:  Sensors (Basel)       Date:  2022-05-23       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.