Literature DB >> 10829385

A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

M Nakagawara1, K Yamakoshi.   

Abstract

A new, portable instrument has been developed for simultaneous monitoring of blood pressure, cardiac output and other cardiovascular haemodynamic variables. The measurements are based on the volume-compensation method and the transthoracic electrical admittance method. The instrument is small and light and can be carried by the subject. The portable unit controls the measurement procedures, performs the blood pressure and cardiac output measurement, processes signals and stores almost 32,000 beats of time-series data in a fully automated manner. A conventional personal computer is used to initialize the measurement system, and to reproduce and evaluate the measurement data. The measurement system provides a means to evaluate in detail, without restriction, the subject's cardiovascular haemodynamic responses to daily physical activities as well as to various psycho-physiological stresses. The paper describes a new, portable, cardiovascular haemodynamic instrument and in-the-field test results. Twelve subjects are monitored for trials, 60-210 min, and fewer than 3% of the data in each trial are artifactual. Artefacts are due mainly to body movements.

Mesh:

Year:  2000        PMID: 10829385     DOI: 10.1007/bf02344683

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  25 in total

1.  Optimalisation of the spot electrode array in impedance cardiography.

Authors:  H H Woltjer; B W Arntzen; H J Bogaard; P M de Vries
Journal:  Med Biol Eng Comput       Date:  1996-01       Impact factor: 2.602

2.  Transthoracic admittance plethysmograph for measuring cardiac output.

Authors:  H Ito; K I Yamakoshi; T Togawa
Journal:  J Appl Physiol       Date:  1976-03       Impact factor: 3.531

3.  Motion artifact from spot and band electrodes during impedance cardiography.

Authors:  M H Qu; Y J Zhang; J G Webster; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1986-11       Impact factor: 4.538

4.  Systolic time intervals as measures of the contractile state of the left ventricular myocardium in man.

Authors:  S S Ahmed; G E Levinson; C J Schwartz; P O Ettinger
Journal:  Circulation       Date:  1972-09       Impact factor: 29.690

5.  Voltage clamp method for the use of electrical admittance plethysmography in human body segments.

Authors:  K Yamakoshi; M Nakagawara
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

6.  Measurement of cardiac output by electrical impedance at rest and during exercise.

Authors:  J C Denniston; J T Maher; J T Reeves; J C Cruz; A Cymerman; R F Grover
Journal:  J Appl Physiol       Date:  1976-01       Impact factor: 3.531

7.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

8.  Noninvasive measurement of hematocrit by electrical admittance plethysmography technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

9.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11

10.  Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance.

Authors:  D P Bernstein
Journal:  Crit Care Med       Date:  1986-10       Impact factor: 7.598

View more
  2 in total

1.  Relationship between salivary Chromogranin-A and stress induced by simulated monotonous driving.

Authors:  Takehiro Yamakoshi; Sang-Bum Park; Won-Cheoul Jang; Kyungho Kim; Yasuhiro Yamakoshi; Hajime Hirose
Journal:  Med Biol Eng Comput       Date:  2009-02-05       Impact factor: 2.602

2.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.