Literature DB >> 7358417

Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

K I Yamakoshi, H Shimazu, T Togawa.   

Abstract

Entities:  

Mesh:

Year:  1980        PMID: 7358417     DOI: 10.1109/TBME.1980.326616

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  28 in total

1.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion.

Authors:  R Raamat; J Talts; K Jagomägi; E Länsimies
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

3.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration.

Authors:  W Chen; T Kobayashi; S Ichikawa; Y Takeuchi; T Togawa
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

4.  Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

5.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

Authors:  H Shimazu; A Kawarada; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

6.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure.

Authors:  P D Baker; D R Westenskow; K Kück
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

7.  Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method.

Authors:  S Tanaka; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

8.  Vibration technique for indirect measurement of diastolic arterial pressure in human fingers.

Authors:  H Shimazu; H Ito; A Kawarada; H Kobayashi; A Hiraiwa; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

9.  Noninvasive measurement of arterial elasticity in various human limbs.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

10.  Noninvasive method for estimating the mean capillary pressure and pre- and postcapillary resistance ratio in human fingers.

Authors:  H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1986-11       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.