Literature DB >> 2622228

Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

H Shimazu, A Kawarada, H Ito, K Yamakoshi.   

Abstract

A new plethysmograph, the electric impedance cuff, was designed for the indirect measurement of blood pressure, volume elastic modulus Ev and compliance Ca in human limb arteries. This comprises a compression chamber filled with electrolyte solution and a tetrapolar electric impedance plethysmograph whose electrodes are placed inside the chamber; the former for controlling transmural arterial pressure Pt, and the latter for detecting total limb volume Vo, mean arterial volume Va and its variation delta Va. Systolic and mean arterial pressure in the upper arms, forearms and fingers were measured by detecting pulsatile impedance variation during the gradual (3-5 mm Hg per heart beat) increase (or decrease) in chamber pressure by the volume oscillometric technique. Diastolic and pulse pressure delta P were calculated from these pressure values. Compliance Ca = delta V/delta P and volume elastic modulus Ev = delta P/(delta Va/Va) were recorded at various Pt levels, controlled by the compression pressure. Although this is a kind of impedance plethysmograph, the volume change in a limb segment can be detected by this method without passing electric current through the limb.

Entities:  

Mesh:

Year:  1989        PMID: 2622228     DOI: 10.1007/bf02441465

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  History of plethysmography.

Authors:  C HYMAN; T WINSOR
Journal:  J Cardiovasc Surg (Torino)       Date:  1961-11       Impact factor: 1.888

2.  Noninvasive measurements of digital arterial pressure and compliance in man.

Authors:  R Nakayama; T Azuma
Journal:  Am J Physiol       Date:  1977-07

3.  Transthoracic admittance plethysmograph for measuring cardiac output.

Authors:  H Ito; K I Yamakoshi; T Togawa
Journal:  J Appl Physiol       Date:  1976-03       Impact factor: 3.531

4.  Noninvasive measurement of the volume elastic modulus in finger arteries using photoelectric plethysmography.

Authors:  H Shimazu; K Yamakoshi; A Kamiya
Journal:  IEEE Trans Biomed Eng       Date:  1986-08       Impact factor: 4.538

5.  Noninvasive method for estimating the mean capillary pressure and pre- and postcapillary resistance ratio in human fingers.

Authors:  H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1986-11       Impact factor: 2.602

6.  Plethysmography.

Authors:  J P Woodcock
Journal:  Biomed Eng       Date:  1974-09

7.  Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography.

Authors:  H Shimazu; K Yamakoshi; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1982-01       Impact factor: 4.538

8.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

9.  Admittance plethysmography for accurate measurement of human limb blood flow.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; H Ito
Journal:  Am J Physiol       Date:  1978-12

10.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11
View more
  4 in total

1.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion.

Authors:  R Raamat; J Talts; K Jagomägi; E Länsimies
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Electrical admittance cuff for noninvasive and simultaneous measurement of haematocrit, arterial pressure and elasticity using volume-oscillometric method.

Authors:  K Yamakoshi; S Tanaka; H Shimazu
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

3.  Significance of plasma D-dimer in relation to the severity of atherosclerosis among patients evaluated by non-invasive indices of cardio-ankle vascular index and carotid intima-media thickness.

Authors:  Shigeru Hayashi
Journal:  Int J Hematol       Date:  2010-06-18       Impact factor: 2.490

4.  A vibration-based approach to quantifying the dynamic elastance of the superficial arterial wall.

Authors:  Jia-Jung Wang; Shing-Hong Liu; Hung-Mao Su; Steven Chang; Wei-Kung Tseng
Journal:  Biomed Eng Online       Date:  2016-04-16       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.