Literature DB >> 6853567

The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements.

J N Insall, R W Hood, L B Flawn, D J Sullivan.   

Abstract

We studied the first 100 consecutive patients (125 knees) to undergo knee arthroplasty with the original total condylar-I prosthesis for either osteoarthritis or osteonecrosis on the Knee Service at The Hospital for Special Surgery. They were followed for an average of 6.6 years (range, five to nine years), which is the longest follow-up of a total knee prosthesis that is still widely used in its original and unmodified form. At five to nine years of follow-up, eleven patients (fourteen knees) were dead and ten patients (eleven knees) could not be traced, leaving 100 knees (seventy-nine patients) for clinical evaluation. This included one knee from which the prosthesis was removed for sepsis at six months, four that were revised for pain, and two that were revised because of subluxation. Two patients had a loose tibial component. Sixty-four knees were rated as excellent and twenty-seven were rated as good. There were two fair and seven poor results. Detailed radiographic evaluation of the 100 knees showed that only minimum changes in the varus or valgus alignment or the fixation of the prosthetic components had occurred with time. At follow-up, 41 per cent of the tibial components showed some evidence of radiolucency, although with the exception of the two loose components just mentioned there were no complete or circumferential radiolucent lines. Most radiolucencies were present by the end of the first postoperative year, and in 81 per cent of the knees there was no further change. Although a special attempt was made to determine any evidence of wear of the polyethylene tibial component, we were unable to demonstrate unequivocal wear in any knee. Our experience had led us to conclude that the long-term success of current total knee designs will probably not be significantly affected by polyethylene wear or loss of component fixation. The majority of failures in our series were attributed to errors in surgical technique.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6853567

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  44 in total

1.  Surgery for the arthritic knee.

Authors:  A E Gross
Journal:  Can Fam Physician       Date:  1985-03       Impact factor: 3.275

2.  Range of motion after total condylar knee arthroplasty.

Authors:  W Menke; B Schmitz; S Salm
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

3.  Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery.

Authors:  Seong Il Bin; Tae Seok Nam
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-28       Impact factor: 4.342

4.  The Self-Aligning knee prosthesis: clinical and radiological outcome and survival analysis at 5-year follow up.

Authors:  M J F Diks; P G Anderson; J C A D Janssen; G van Stralen; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-14       Impact factor: 4.342

5.  Posteriorly stabilised (Insall-Burstein) total condylar knee arthroplasty. A follow-up study of 157 knees.

Authors:  D V Patel; P M Aichroth; J S Wand
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

6.  Gap balancing versus measured resection technique for total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Raymond H Kim; Adrija Sharma
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

7.  In vivo kinematics after a cruciate-substituting TKA.

Authors:  Jan Victor; John Kyle P Mueller; Richard D Komistek; Adrija Sharma; Matthew C Nadaud; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2009-09-04       Impact factor: 4.176

8.  Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.

Authors:  Eun-Kyoo Song; Hong-An Lim; Sang-Don Joo; Sung-Kyu Kim; Keun-Bae Lee; Jong-Keun Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

9.  Patellofemoral function in total condylar knee arthroplasty.

Authors:  O Sneppen; G H Gudmundsson; C Bünger
Journal:  Int Orthop       Date:  1985       Impact factor: 3.075

10.  Knee arthroplasty for spontaneous osteonecrosis of the knee: unicompartimental vs bicompartimental knee arthroplasty.

Authors:  S Radke; N Wollmerstedt; A Bischoff; J Eulert
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-09-24       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.