Literature DB >> 19789934

Gap balancing versus measured resection technique for total knee arthroplasty.

Douglas A Dennis1, Richard D Komistek, Raymond H Kim, Adrija Sharma.   

Abstract

Multiple differing surgical techniques are currently utilized to perform total knee arthroplasty (TKA). We compared knee arthroplasties performed using either a measured resection or gap balancing technique to determine if either operative technique provides superior coronal plane stability as measured by assessment of the incidence and magnitude of femoral condylar lift-off. We performed 40 TKA using a measured resection technique (20 PCL-retaining and 20 PCL-substituting) and 20 PCL-substituting TKA were implanted using gap balancing. All subjects were analyzed fluoroscopically while performing a deep knee bend. The incidence of coronal instability (femoral condylar lift-off) was then determined using a 3-D model fitting technique. The incidence of lift-off greater than 0.75 mm was 80% (maximum, 2.9 mm) and 70% (maximum, 2.5 mm) for the PCL-retaining and substituting TKA groups performed using measured resection versus 35% (maximum, 0.88 mm) for the gap-balanced group. Lift-off greater than 1 mm occurred in 60% and 45% of the PCL-retaining and -substituting TKA using measured resection versus none in the gap-balanced group. Rotation of the femoral component using a gap balancing technique resulted in better coronal stability which we suggest will improve functional performance and reduce polyethylene wear.

Entities:  

Mesh:

Year:  2010        PMID: 19789934      PMCID: PMC2795818          DOI: 10.1007/s11999-009-1112-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  25 in total

1.  Rotational malalignment of the femoral component in total knee arthroplasty.

Authors:  T K Fehring
Journal:  Clin Orthop Relat Res       Date:  2000-11       Impact factor: 4.176

2.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

3.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  IEEE Trans Med Imaging       Date:  2003-12       Impact factor: 10.048

4.  In vivo fluoroscopic analysis of fixed-bearing total knee replacements.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

5.  Early revision for component malrotation in total knee arthroplasty.

Authors:  Stephen J Incavo; John J Wild; Kathryn M Coughlin; Bruce D Beynnon
Journal:  Clin Orthop Relat Res       Date:  2007-05       Impact factor: 4.176

6.  The clinical consequences of flexion gap asymmetry in total knee arthroplasty.

Authors:  Jose Romero; Thomas Stähelin; Chistoph Binkert; Christian Pfirrmann; Jurg Hodler; Oliver Kessler
Journal:  J Arthroplasty       Date:  2007-02       Impact factor: 4.757

7.  Measured resection: an outdated technique in total knee arthroplasty.

Authors:  Douglas A Dennis
Journal:  Orthopedics       Date:  2008-09       Impact factor: 1.390

8.  Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty.

Authors:  J P Mantas; R D Bloebaum; J G Skedros; A A Hofmann
Journal:  J Arthroplasty       Date:  1992-12       Impact factor: 4.757

9.  Malrotation causing patellofemoral complications after total knee arthroplasty.

Authors:  R A Berger; L S Crossett; J J Jacobs; H E Rubash
Journal:  Clin Orthop Relat Res       Date:  1998-11       Impact factor: 4.176

10.  Fixed- versus mobile-bearing total knee arthroplasty: technical issues and surgical tips.

Authors:  Lawrence S Crossett
Journal:  Orthopedics       Date:  2002-02       Impact factor: 1.390

View more
  70 in total

1.  Effects of four different surgical approaches on intra-operative joint gap in posterior-stabilized total knee arthroplasty.

Authors:  Yasuo Niki; Yuki Takeda; Hiroya Kanagawa; Wataru Iwamoto; Hideo Matsumoto; Hiroyuki Enomoto; Yoshiaki Toyama; Yasunori Suda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-08       Impact factor: 4.342

2.  Partial resection of the PCL insertion site during tibial preparation in cruciate-retaining TKA.

Authors:  Hans Feyen; Nick Van Opstal; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-22       Impact factor: 4.342

3.  [Soft tissue balanced navigation of total knee arthroplasties].

Authors:  C Schnurr; I Stolzenberg; J Nessler; P Eysel; P König
Journal:  Oper Orthop Traumatol       Date:  2012-04       Impact factor: 1.154

4.  Can we define envelope of laxity during navigated knee arthroplasty?

Authors:  K M Ghosh; A P Blain; L Longstaff; S Rushton; A A Amis; D J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

5.  Improved kinematics of total knee replacement following partially navigated modified gap-balancing technique.

Authors:  Clemens Baier; Wolfgang Fitz; Ben Craiovan; Armin Keshmiri; Sebastian Winkler; Robert Springorum; Joachim Grifka; Johannes Beckmann
Journal:  Int Orthop       Date:  2013-10-15       Impact factor: 3.075

6.  Lessons learned from selective soft-tissue release for gap balancing in primary total knee arthroplasty: an analysis of 1216 consecutive total knee arthroplasties: AAOS exhibit selection.

Authors:  Christopher L Peters; Chris Jimenez; Jill Erickson; Mike B Anderson; Christopher E Pelt
Journal:  J Bone Joint Surg Am       Date:  2013-10-16       Impact factor: 5.284

7.  Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique.

Authors:  Hee-Nee Pang; Seng-Jin Yeo; Hwei-Chi Chong; Pak-Lin Chin; Johnny Ong; Ngai-Nung Lo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-03-30       Impact factor: 4.342

8.  Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-20       Impact factor: 4.342

9.  Mobile-bearing prosthesis and intraoperative gap balancing are not predictors of superior knee flexion: a prospective randomized study.

Authors:  Yukihide Minoda; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Shigekazu Mizokawa; Maki Itokazu; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-17       Impact factor: 4.342

10.  Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Jan Victor; Jan Dujardin; Hilde Vandenneucker; Nele Arnout; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.