Literature DB >> 19760468

In vivo kinematics after a cruciate-substituting TKA.

Jan Victor1, John Kyle P Mueller, Richard D Komistek, Adrija Sharma, Matthew C Nadaud, Johan Bellemans.   

Abstract

UNLABELLED: Patterns of motion in the native knee show substantial variability. Guided motion prosthetic designs offer stability but may limit natural variability. To assess these limits, we therefore determined the in vivo kinematic patterns for patients having a cruciate-substituting TKA of one design and determined the intersurgeon variability associated with a guided-motion prosthetic design. Three-dimensional femorotibial contact positions were evaluated for 86 TKAs in 80 subjects from three different surgeons using fluoroscopy during a weightbearing deep knee bend. The average posterior femoral rollback of the medial and lateral condyles for all TKAs from full extension to maximum flexion was -14.0 mm and -23.0 mm, respectively. The average axial tibiofemoral rotation from full extension to maximum flexion for all TKAs was 10.8 degrees. The average weightbearing range of motion (ROM) was 109 degrees (range, 60 degrees-150 degrees; standard deviation, 18.7 degrees). Overall, the TKA showed axial rotation patterns similar to those of the normal knee, although less in magnitude. Surgeon-to-surgeon comparison revealed dissimilarities, showing the surgical technique and soft tissue handling influence kinematics in a guided-motion prosthetic design. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2009        PMID: 19760468      PMCID: PMC2816757          DOI: 10.1007/s11999-009-1072-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  38 in total

1.  Femoral condylar lift-off in vivo in total knee arthroplasty.

Authors:  D A Dennis; R D Komistek; S A Walker; E J Cheal; J B Stiehl
Journal:  J Bone Joint Surg Br       Date:  2001-01

2.  Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset.

Authors:  J Bellemans; S Banks; J Victor; H Vandenneucker; A Moemans
Journal:  J Bone Joint Surg Br       Date:  2002-01

3.  In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty.

Authors:  Kim C Bertin; Richard D Komistek; Douglas A Dennis; William A Hoff; Dylan T Anderson; Todd Langer
Journal:  J Arthroplasty       Date:  2002-12       Impact factor: 4.757

4.  Contrary view: wear is not an issue.

Authors:  Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

5.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  IEEE Trans Med Imaging       Date:  2003-12       Impact factor: 10.048

6.  Correlation between condylar lift-off and femoral component alignment.

Authors:  John N Insall; Giles R Scuderi; Richard D Komistek; Kevin Math; Douglas A Dennis; Dylan T Anderson
Journal:  Clin Orthop Relat Res       Date:  2002-10       Impact factor: 4.176

7.  In vivo contact stresses during activities of daily living after knee arthroplasty.

Authors:  Darryl D D'Lima; Nikolai Steklov; Benjamin J Fregly; Scott A Banks; Clifford W Colwell
Journal:  J Orthop Res       Date:  2008-12       Impact factor: 3.494

8.  Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI.

Authors:  P F Hill; V Vedi; A Williams; H Iwaki; V Pinskerova; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  2000-11

9.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee.

Authors:  H Iwaki; V Pinskerova; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  2000-11

10.  In vivo fluoroscopic analysis of the normal human knee.

Authors:  Richard D Komistek; Douglas A Dennis; Mohamed Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

View more
  29 in total

1.  Posterior dislocation in total knee replacement: a price for deep flexion?

Authors:  Nele Arnout; Hilde Vandenneucker; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-07       Impact factor: 4.342

2.  In vivo determination of cam-post engagement in fixed and mobile-bearing TKA.

Authors:  Sumesh M Zingde; Filip Leszko; Adrija Sharma; Mohamed R Mahfouz; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

3.  Fully automatic initialization of two-dimensional-three-dimensional medical image registration using hybrid classifier.

Authors:  Jing Wu; Emam E Abdel Fatah; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-02

4.  Tibiofemoral helical axis of motion during the full gait cycle measured using biplane radiography.

Authors:  Tom Gale; William Anderst
Journal:  Med Eng Phys       Date:  2020-10-28       Impact factor: 2.242

5.  Is there a gold standard for TKA tibial component rotational alignment?

Authors:  Erin E Hutter; Jeffrey F Granger; Matthew D Beal; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

6.  Functional versus patient-reported outcome of the bicruciate and the standard condylar-stabilizing total knee arthroplasty.

Authors:  Alberto Vascellari; Stefano Schiavetti; Enrico Rebuzzi; Nicolò Coletti
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-02-27

7.  Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs.

Authors:  N Arnout; L Vanlommel; J Vanlommel; J P Luyckx; L Labey; B Innocenti; J Victor; J Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-22       Impact factor: 4.342

8.  Kinematic behaviour and soft tissue management in guided motion total knee replacement.

Authors:  Camilla Halewood; Michael Risebury; Neil P Thomas; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-19       Impact factor: 4.342

9.  Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study.

Authors:  Kristin D Zhao; Ephraim I Ben-Abraham; Dixon J Magnuson; Jon J Camp; Lawrence J Berglund; Kai-Nan An; Gert Bronfort; Ralph E Gay
Journal:  J Biomech Eng       Date:  2016-05       Impact factor: 2.097

10.  Bi-cruciate stabilized total knee arthroplasty can reduce the risk of knee instability associated with posterior tibial slope.

Authors:  Masaru Hada; Hideki Mizu-Uchi; Ken Okazaki; Takao Kaneko; Koji Murakami; Yuan Ma; Satoshi Hamai; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-22       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.