Literature DB >> 20236879

Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Adam Wunderlich1, Frederic Noo.   

Abstract

We introduce a new estimator for noise variance in tomographic images reconstructed using algorithms of the filtered backprojection type. The new estimator operates on data acquired from repeated scans of the object under examination, is unbiased, and is shown to have significantly lower variance than the conventional unbiased estimator for many scenarios of practical interest. We provide an extensive theoretical analysis of this estimator, highlighting the circumstances under which it is most effective. This analysis includes both general and specific data-correlation patterns. Moreover, we have applied our estimator to real X-ray computed tomography data and present preliminary results that support the theory and provide experimental evidence of the new estimator's efficacy.

Entities:  

Mesh:

Year:  2010        PMID: 20236879      PMCID: PMC2910868          DOI: 10.1109/TMI.2009.2034961

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  21 in total

1.  Favorable noise uniformity properties of Fourier-based interpolation and reconstruction approaches in single-slice helical computed tomography.

Authors:  Patrick J La Rivière; Xiaochuan Pan
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

2.  Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.

Authors:  Xiaochuan Pan; Lifeng Yu
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

3.  Half-scan fan-beam computed tomography with improved noise and resolution properties.

Authors:  Lifeng Yu; Xiaochuan Pan
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

4.  Cone-beam reconstruction using the backprojection of locally filtered projections.

Authors:  Jed D Pack; Frédéric Noo; Rolf Clackdoyle
Journal:  IEEE Trans Med Imaging       Date:  2005-01       Impact factor: 10.048

5.  An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

Authors:  Jing Wang; Hongbing Lu; Tianfang Li; Zhengrong Liang
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

6.  Estimation of the local statistical noise in emission computed tomography.

Authors:  N M Alpert; D A Chesler; J A Correia; R H Ackerman; J Y Chang; S Finklestein; S M Davis; G L Brownell; J M Taveras
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

7.  Validation of CT dose-reduction simulation.

Authors:  Parinaz Massoumzadeh; Steven Don; Charles F Hildebolt; Kyongtae T Bae; Bruce R Whiting
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

8.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

9.  Analytic noise-propagation in indirect fan-beam FBP reconstruction.

Authors:  Anja Borsdorf; Steffen Kappler; Rainer Raupach; Joachim Hornegger
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

10.  A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography.

Authors:  R H Huesman
Journal:  Phys Med Biol       Date:  1984-05       Impact factor: 3.609

View more
  2 in total

1.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

2.  A Direct Algorithm for Optimization Problems With the Huber Penalty.

Authors:  Jingyan Xu; Frederic Noo; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2017-10-05       Impact factor: 10.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.