The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Scott S Hsieh1, Norbert J Pelc.   

Abstract

Photon counting x-ray detectors (PCXDs) offer several advantages compared to standard energy-integrating x-ray detectors, but also face significant challenges. One key challenge is the high count rates required in CT. At high count rates, PCXDs exhibit count rate loss and show reduced detective quantum efficiency in signal-rich (or high flux) measurements. In order to reduce count rate requirements, a dynamic beam-shaping filter can be used to redistribute flux incident on the patient. We study the piecewise-linear attenuator in conjunction with PCXDs without energy discrimination capabilities. We examined three detector models: the classic nonparalyzable and paralyzable detector models, and a 'hybrid' detector model which is a weighted average of the two which approximates an existing, real detector (Taguchi et al 2011 Med. Phys. 38 1089-102). We derive analytic expressions for the variance of the CT measurements for these detectors. These expressions are used with raw data estimated from DICOM image files of an abdomen and a thorax to estimate variance in reconstructed images for both the dynamic attenuator and a static beam-shaping ('bowtie') filter. By redistributing flux, the dynamic attenuator reduces dose by 40% without increasing peak variance for the ideal detector. For non-ideal PCXDs, the impact of count rate loss is also reduced. The nonparalyzable detector shows little impact from count rate loss, but with the paralyzable model, count rate loss leads to noise streaks that can be controlled with the dynamic attenuator. With the hybrid model, the characteristic count rates required before noise streaks dominate the reconstruction are reduced by a factor of 2 to 3. We conclude that the piecewise-linear attenuator can reduce the count rate requirements of the PCXD in addition to improving dose efficiency. The magnitude of this reduction depends on the detector, with paralyzable detectors showing much greater benefit than nonparalyzable detectors.

Entities:  

Mesh:

Year:  2014        PMID: 24819415      PMCID: PMC4091805          DOI: 10.1088/0031-9155/59/11/2829

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

Authors:  Hans Bornefalk; Mats Danielsson
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

3.  A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.

Authors:  Xiangyang Tang; Jiang Hsieh; Akira Hagiwara; Roy A Nilsen; Jean-Baptiste Thibault; Evgeny Drapkin
Journal:  Phys Med Biol       Date:  2005-08-02       Impact factor: 3.609

4.  A prototype table-top inverse-geometry volumetric CT system.

Authors:  Taly Gilat Schmidt; Josh Star-Lack; N Robert Bennett; Samuel R Mazin; Edward G Solomon; Rebecca Fahrig; Norbert J Pelc
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

5.  A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.

Authors:  Xiangyang Tang; Jiang Hsieh; Roy A Nilsen; Sandeep Dutta; Dmitry Samsonov; Akira Hagiwara
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

6.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

7.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

8.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

9.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

10.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects.

Authors:  Katsuyuki Taguchi; Mengxi Zhang; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; Einar Nygard; Neal E Hartsough; Benjamin M W Tsui; William C Barber
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

View more
  6 in total

1.  An Investigation of Low-Dose 3D Scout Scans for Computed Tomography.

Authors:  Juliana Gomes; Grace J Gang; Aswin Mathews; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

2.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

3.  Generation and analysis of clinically relevant breast imaging x-ray spectra.

Authors:  Andrew M Hernandez; J Anthony Seibert; Anita Nosratieh; John M Boone
Journal:  Med Phys       Date:  2017-05-04       Impact factor: 4.071

4.  Reconstruction of three-dimensional tomographic patient models for radiation dose modulation in CT from two scout views using deep learning.

Authors:  Juan C Montoya; Chengzhu Zhang; Yinsheng Li; Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2022-01-06       Impact factor: 4.506

5.  A prototype piecewise-linear dynamic attenuator.

Authors:  Scott S Hsieh; Mark V Peng; Christopher A May; Picha Shunhavanich; Dominik Fleischmann; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2016-06-10       Impact factor: 3.609

6.  Technical Note: spektr 3.0-A computational tool for x-ray spectrum modeling and analysis.

Authors:  J Punnoose; J Xu; A Sisniega; W Zbijewski; J H Siewerdsen
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.