Literature DB >> 18078912

Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Brian E Nett1, Shuai Leng, Joseph N Zambelli, Scott B Reeder, Michael A Speidel, Guang-Hong Chen.   

Abstract

RATIONALE AND
OBJECTIVES: Existing cardiac imaging methods do not allow for improved temporal resolution when considering a targeted region of interest (ROI). The imaging method presented here enables improved temporal resolution for ROI imaging (namely, a reconstruction volume smaller than the complete field of view). Clinically, temporally targeted reconstruction would not change the primary means of reconstructing and evaluating images, but rather would enable the adjunct technique of ROI imaging, with improved temporal resolution compared with standard reconstruction ( approximately 20% smaller temporal scan window). In gated cardiac computed tomography (CT) scans improved temporal resolution directly translates into a reduction in motion artifacts for rapidly moving objects such as the coronary arteries.
MATERIALS AND METHODS: Retrospectively electrocardiogram gated coronary angiography data from a 64-slice CT system were used. A motion phantom simulating the motion profile of a coronary artery was constructed and scanned. Additionally, an in vivo study was performed using a porcine model. Comparisons between the new reconstruction technique and the standard reconstruction are given for an ROI centered on the right coronary artery, and a pulmonary ROI.
RESULTS: In both a well-controlled motion model and a porcine model results show a decrease in motion induced artifacts including motion blur and streak artifacts from contrast enhanced vessels within the targeted ROIs, as assessed through both qualitative and quantitative observations.
CONCLUSION: Temporally targeted reconstruction techniques demonstrate the potential to reduce motion artifacts in coronary CT. Further study is warranted to demonstrate the conditions under which this technique will offer direct clinical utility. Improvement in temporal resolution for gated cardiac scans has implications for improving: contrast enhanced CT angiography, calcium scoring, and assessment of the pulmonary anatomy.

Mesh:

Year:  2008        PMID: 18078912      PMCID: PMC2693077          DOI: 10.1016/j.acra.2007.07.003

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  34 in total

1.  A new framework of image reconstruction from fan beam projections.

Authors:  Guang-Hong Chen
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

2.  Feldkamp-type VOI reconstruction from super-short-scan cone-beam data.

Authors:  Hengyong Yu; Ge Wang
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Authors:  Xiaochuan Pan; Yu Zou; Dan Xia
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

4.  64 slice cardiovascular CT in the emergency department: concepts and first experiences.

Authors:  G Savino; C Herzog; P Costello; U J Schoepf
Journal:  Radiol Med       Date:  2006-05-29       Impact factor: 3.469

5.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Authors:  Jiang Hsieh; John Londt; Melissa Vass; Jay Li; Xiangyang Tang; Darin Okerlund
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

6.  Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm.

Authors:  Martin King; Xiaochuan Pan; Lifeng Yu; Maryellen Giger
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

7.  Rest period duration of the coronary arteries: implications for magnetic resonance coronary angiography.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

8.  Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.

Authors:  Tingliang Zhuang; Shuai Leng; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2004-12-21       Impact factor: 3.609

9.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

10.  Duration of diastole and its phases as a function of heart rate during supine bicycle exercise.

Authors:  Charles S Chung; Mustafa Karamanoglu; Sándor J Kovács
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-06-24       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.