Literature DB >> 16481694

Noise simulation in cone beam CT imaging with parallel computing.

Shu-Ju Tu1, Chris C Shaw, Lingyun Chen.   

Abstract

We developed a computer noise simulation model for cone beam computed tomography imaging using a general purpose PC cluster. This model uses a mono-energetic x-ray approximation and allows us to investigate three primary performance components, specifically quantum noise, detector blurring and additive system noise. A parallel random number generator based on the Weyl sequence was implemented in the noise simulation and a visualization technique was accordingly developed to validate the quality of the parallel random number generator. In our computer simulation model, three-dimensional (3D) phantoms were mathematically modelled and used to create 450 analytical projections, which were then sampled into digital image data. Quantum noise was simulated and added to the analytical projection image data, which were then filtered to incorporate flat panel detector blurring. Additive system noise was generated and added to form the final projection images. The Feldkamp algorithm was implemented and used to reconstruct the 3D images of the phantoms. A 24 dual-Xeon PC cluster was used to compute the projections and reconstructed images in parallel with each CPU processing 10 projection views for a total of 450 views. Based on this computer simulation system, simulated cone beam CT images were generated for various phantoms and technique settings. Noise power spectra for the flat panel x-ray detector and reconstructed images were then computed to characterize the noise properties. As an example among the potential applications of our noise simulation model, we showed that images of low contrast objects can be produced and used for image quality evaluation.

Mesh:

Year:  2006        PMID: 16481694      PMCID: PMC1995743          DOI: 10.1088/0031-9155/51/5/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware.

Authors:  K Mueller; R Yagel
Journal:  IEEE Trans Med Imaging       Date:  2000-12       Impact factor: 10.048

2.  Efficient Monte Carlo simulations using a shuffled nested Weyl sequence random number generator.

Authors:  K V Tretiakov; K W Wojciechowski
Journal:  Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics       Date:  1999-12

3.  Additive noise properties of active matrix flat-panel imagers.

Authors:  M Maolinbay; Y El-Mohri; L E Antonuk; K W Jee; S Nassif; X Rong; Q Zhao
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

4.  Geometric random inner products: a family of tests for random number generators.

Authors:  Shu-Ju Tu; Ephraim Fischbach
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2003-01-28

5.  Regional improvement of signal-to-noise and contrast-to-noise ratios in dual-screen CR chest imaging--a phantom study.

Authors:  X Liu; C C Shaw
Journal:  Med Phys       Date:  2001-06       Impact factor: 4.071

6.  Pseudorandom number generator for massively parallel molecular-dynamics simulations.

Authors: 
Journal:  Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics       Date:  1994-08

7.  Noise characteristics for cone beam collimators: a comparison with parallel hole collimator.

Authors:  L J Hahn; R J Jaszczak; G T Gullberg; C E Floyd; S H Manglos; K L Greer; R E Coleman
Journal:  Phys Med Biol       Date:  1988-05       Impact factor: 3.609

8.  Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.

Authors:  K Faulkner; B M Moores
Journal:  Phys Med Biol       Date:  1984-11       Impact factor: 3.609

9.  The noise power spectrum in computed X-ray tomography.

Authors:  S J Riederer; N J Pelc; D A Chesler
Journal:  Phys Med Biol       Date:  1978-05       Impact factor: 3.609

10.  A-Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2004-01       Impact factor: 4.071

View more
  11 in total

1.  Numerical study of water diffusion in biological tissues using an improved finite difference method.

Authors:  Junzhong Xu; Mark D Does; John C Gore
Journal:  Phys Med Biol       Date:  2007-03-12       Impact factor: 3.609

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT--a preliminary study.

Authors:  Lingyun Chen; Chris C Shaw; Mustafa C Altunbas; Chao-Jen Lai; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 4.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

5.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; A Jay Khanna; Gary L Gallia; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

7.  Surface-constrained nonrigid registration for dose monitoring in prostate cancer radiotherapy.

Authors:  Guillaume Cazoulat; Antoine Simon; Aurelien Dumenil; Khemara Gnep; Renaud de Crevoisier; Oscar Acosta; Pascal Haigron
Journal:  IEEE Trans Med Imaging       Date:  2014-04-01       Impact factor: 10.048

8.  Computed tomography for imaging the breast.

Authors:  John M Boone; Alex L C Kwan; Kai Yang; George W Burkett; Karen K Lindfors; Thomas R Nelson
Journal:  J Mammary Gland Biol Neoplasia       Date:  2006-04       Impact factor: 2.673

Review 9.  The quality/safety medical index: implementation and analysis.

Authors:  Bruce I Reiner
Journal:  J Digit Imaging       Date:  2015-02       Impact factor: 4.056

10.  Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique.

Authors:  Jessie Q Xia; Joseph Y Lo; Kai Yang; Carey E Floyd; John M Boone
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.