Analysis of the significance of scattered radiation in reduced dose mammography, including magnification effects, scatter suppression, and focal spot and detector blurring.

E P Muntz.   

Abstract

A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of the important trade-offs. The major uncertainties in the analysis probably have to do with the formal equivalence, that is implicit in the aperture theory, between large area and detail contrast, as well as the output versus focal spot relationship that was adopted. Also, there are important questions about specifying motion unsharpness as a function of exposure time in mammography examinations.

Mesh:

Year:  1979        PMID: 460060     DOI: 10.1118/1.594540

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  The effect of the antiscatter grid on full-field digital mammography phantom images.

Authors:  D P Chakraborty
Journal:  J Digit Imaging       Date:  1999-02       Impact factor: 4.056

2.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

3.  Study of the Generalized MTF and DQE for a New Microangiographic System.

Authors:  Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-05-06

4.  Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

Authors:  Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

5.  Evaluation and Comparison of High-Resolution (HR) and High-Light (HL) Phosphors in the Micro-Angiographic Fluoroscope (MAF) using Generalized Linear Systems Analyses (GMTF, GDQE) that include the Effect of Scatter, Magnification and Detector Characteristics.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

6.  Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment.

Authors:  Iacovos S Kyprianou; Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Brandon D Gallas; Kyle J Myers
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

7.  Generalized Performance Evaluation of X-ray Image Intensifier compared with a Microangiographic System.

Authors:  Girijesh K Yadava; Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

8.  Generalized Objective Performance Assessment of a New High-Sensitivity Microangiographic Fluoroscopic (HSMAF) Imaging System.

Authors:  Girijesh K Yadava; Stephen Rudin; Andrew T Kuhls-Gilcrist; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

9.  Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Radiology       Date:  2008-12       Impact factor: 11.105

10.  Focal spot measurements using a digital flat panel detector.

Authors:  Amit Jain; A Panse; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.