Literature DB >> 3950245

Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values.

K B Sagar, L S Wann, W H Paulsen, D W Romhilt.   

Abstract

Doppler echocardiographic characteristics of normally functioning Hancock and Björk-Shiley prostheses in the mitral and aortic positions were studied in 50 patients whose valvular function was considered normal by clinical evaluation. Doppler studies were also performed in 46 patients with suspected malfunction of Hancock and Björk-Shiley valves and who subsequently underwent cardiac catheterization. Mean gradients were estimated for both mitral and aortic valve prostheses and valve area was calculated for the mitral prostheses. Doppler prosthetic mitral valve gradient and valve area showed good correlation with values obtained with cardiac catheterization (r = 0.93 and 0.97, respectively) for both types of prosthetic valves. The correlation coefficient (r = 0.93) for mean prosthetic aortic valve gradient was also good, although Doppler echocardiography overestimated the mean gradient at lower degrees of obstruction. Regurgitation of Hancock and Björk-Shiley prostheses in the mitral and aortic positions was correctly diagnosed. These results suggest that Doppler echocardiography is a reliable method for the characterization of normal and abnormal prosthetic valve function.

Entities:  

Mesh:

Year:  1986        PMID: 3950245     DOI: 10.1016/s0735-1097(86)80480-6

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.

Authors:  J Chambers; G Jackson; D Jewitt
Journal:  Br Heart J       Date:  1990-03

2.  Doppler measurement of cardiac output across prosthetic mitral valves.

Authors:  H Dittmann; W Voelker; K R Karsch; L Seipel
Journal:  Klin Wochenschr       Date:  1990-03-05

3.  Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses.

Authors:  J Chambers; N McLoughlin; A Rapson; G Jackson
Journal:  Br Heart J       Date:  1988-12

Review 4.  Echocardiography.

Authors:  J B Chambers; M J Monaghan; G Jackson
Journal:  BMJ       Date:  1988-10-29

5.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

Review 6.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

7.  Colour flow Doppler mapping in the assessment of prosthetic valve regurgitation.

Authors:  J Chambers; M Monaghan; G Jackson
Journal:  Br Heart J       Date:  1989-07

8.  Doppler echocardiography in prosthetic valve dysfunction. Diagnostic value in twenty cases.

Authors:  B Verges; A Laflêche; M C Malergue
Journal:  Int J Card Imaging       Date:  1987
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.