Literature DB >> 3224053

Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses.

J Chambers1, N McLoughlin, A Rapson, G Jackson.   

Abstract

To test the validity of a relation between the pressure half time and the diastolic time interval, previously shown in a pulse duplication system, eight patients with prosthetic mitral valves and permanent pacemaker systems were studied. Recordings were made from the apex by continuous wave or pulsed Doppler echocardiography at heart rates between 75 and 150 beats/min. The pressure half time was found to be closely correlated with the diastolic time interval although there was individual variation and in three prostheses the pressure half time attained a plateau when the diastolic time interval was more than 300 ms. It is likely that the orifice area is the main controller of pressure half time where there is stenosis of the prosthesis, but that other factors such as ventricular or atrial compliance and the diastolic time interval may modify or obscure the effect of orifice area in normally functioning prosthetic valves.

Entities:  

Mesh:

Year:  1988        PMID: 3224053      PMCID: PMC1224891          DOI: 10.1136/hrt.60.6.502

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  13 in total

1.  Atrioventricular pressure half-time. Measure of mitral valve orifice area.

Authors:  A J Libanoff; S Rodbard
Journal:  Circulation       Date:  1968-07       Impact factor: 29.690

2.  Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Authors:  I P Panidis; J Ross; G S Mintz
Journal:  J Am Coll Cardiol       Date:  1986-08       Impact factor: 24.094

3.  Doppler echocardiographic characteristics of the Carpentier-Edwards xenograft.

Authors:  J L Gibbs; G A Wharton; G J Williams
Journal:  Eur Heart J       Date:  1986-04       Impact factor: 29.983

4.  Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values.

Authors:  K B Sagar; L S Wann; W H Paulsen; D W Romhilt
Journal:  J Am Coll Cardiol       Date:  1986-03       Impact factor: 24.094

5.  Ultrasonic assessment of the St. Jude prosthetic valve: M mode, two-dimensional, and Doppler echocardiography.

Authors:  I R Weinstein; J P Marbarger; J E Pérez
Journal:  Circulation       Date:  1983-11       Impact factor: 29.690

6.  Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography.

Authors:  B R Brodie; W Grossman; L McLaurin; P J Starek; E Craige
Journal:  Circulation       Date:  1976-01       Impact factor: 29.690

7.  Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound.

Authors:  L Hatle; B Angelsen; A Tromsdal
Journal:  Circulation       Date:  1979-11       Impact factor: 29.690

8.  Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

Authors:  I A Simpson; I J Reece; A B Houston; I Hutton; D J Wheatley; S M Cobbe
Journal:  Br Heart J       Date:  1986-07

9.  Assessment of mitral Björk-Shiley prosthetic dysfunction using digitised M mode echocardiography.

Authors:  K D Dawkins; L Cotter; D G Gibson
Journal:  Br Heart J       Date:  1984-02

10.  Doppler echocardiographic evaluation of patients with porcine mitral valves.

Authors:  T Ryan; W F Armstrong; J C Dillon; H Feigenbaum
Journal:  Am Heart J       Date:  1986-02       Impact factor: 4.749

View more
  2 in total

1.  Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.

Authors:  J Chambers; G Jackson; D Jewitt
Journal:  Br Heart J       Date:  1990-03

2.  Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.

Authors:  P Weiss; A Hoffmann; D Burckhardt
Journal:  Br Heart J       Date:  1992-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.