Doppler measurement of cardiac output across prosthetic mitral valves.

H Dittmann1, W Voelker, K R Karsch, L Seipel.   

Abstract

In 46 patients with a normal functioning mitral valve prosthesis (15 St. Jude, 19 Medtronic Hall, 12 Hancock) cardiac output was measured by pulsed Doppler echocardiography across the valve prosthesis. Simultaneously cardiac output was determined by thermodilution or pulsed Doppler echocardiography in the left ventricular outflow tract (2.8 l/min-9.5 l/min). The prosthetic valve area was calculated using the pressure half-time method. Cardiac output was calculated by multiplying time-velocity integrals with the mitral valve area. Cardiac output measurements across the mitral prosthesis correlated significantly with thermodilution (r = 0.96, SEE = 0.400 l/min) and pulsed Doppler echocardiography flow measurements in the left ventricular outflow tract (r = 0.82, SEE = 0.679 l/min). The mean percent error of the Doppler transmitral flow measurement was 10.8%. Doppler transmitral flow underestimated cardiac output valves of more than 6.5 l/min in 6 of 7 patients. Cardiac output measurements across Hancock (SEE = 0.473 l/min) and St. Jude prostheses (SEE = 0.538 l/min) were more accurate than across Medtronic Hall prostheses (SEE = 0.847 l/min). Cardiac output can be calculated by pulsed Doppler echocardiography across normal functioning mitral prostheses. Due to the different flow dynamics the accuracy of cardiac output measurement depends on the prosthetic valve type. Reliable measurements of cardiac output can be performed across Hancock and St. Jude prostheses only. This method is limited in volume flow measurements across Medtronic Hall prostheses.

Entities:  

Mesh:

Year:  1990        PMID: 2325355     DOI: 10.1007/bf02116054

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  26 in total

1.  Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Authors:  I P Panidis; J Ross; G S Mintz
Journal:  J Am Coll Cardiol       Date:  1986-08       Impact factor: 24.094

2.  Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.

Authors:  G T Wilkins; L D Gillam; G L Kritzer; R A Levine; I F Palacios; A E Weyman
Journal:  Circulation       Date:  1986-10       Impact factor: 29.690

3.  [Doppler echocardiography normal values in various types of mitral valve prostheses].

Authors:  J M Curtius; H Pawelzik; B Mittmann; H W Breuer; F Loogen
Journal:  Z Kardiol       Date:  1987-01

4.  Flow pattern and velocity field distal to human aortic and artificial heart valves as measured simultaneously by ultramicroscope anemometry in cylindrical glass tubes.

Authors:  D Schramm; W Baldauf; H Meisner
Journal:  Thorac Cardiovasc Surg       Date:  1980-04       Impact factor: 1.827

Review 5.  Doppler mitral pressure half-time: a clinical tool in search of theoretical justification.

Authors:  J D Thomas; A E Weyman
Journal:  J Am Coll Cardiol       Date:  1987-10       Impact factor: 24.094

6.  Problems related to the assessment of fluid velocity and volume flow in valve regurgitation using ultrasound Doppler technique.

Authors:  B Wranne; P Ask; D Loyd
Journal:  Eur Heart J       Date:  1987-08       Impact factor: 29.983

7.  Pressure drop and velocity fields at four mechanical heart valve prostheses: Björk-Shiley Standard, Björk-Shiley Concave-Convex, Hall-Kaster and St. Jude Medical.

Authors:  K H Bruss; H Reul; J van Gilse; E Knott
Journal:  Life Support Syst       Date:  1983 Jan-Mar

8.  Bileaflet, tilting disc and porcine aortic valve substitutes: in vitro hydrodynamic characteristics.

Authors:  A P Yoganathan; A Chaux; R J Gray; Y R Woo; M DeRobertis; F P Williams; J M Matloff
Journal:  J Am Coll Cardiol       Date:  1984-02       Impact factor: 24.094

9.  Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves.

Authors:  G A Williams; A J Labovitz
Journal:  Am J Cardiol       Date:  1985-08-01       Impact factor: 2.778

10.  Obstructic characteristics of Björk-Shiley, Hancock, and Lillehei-Kaster prosthetic mitral valves in the immediate postoperative period.

Authors:  J Holen; J Hìe; B Semb
Journal:  Acta Med Scand       Date:  1978
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.