Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.

J Chambers1, G Jackson, D Jewitt.   

Abstract

Pressure half time has been assumed to be a relatively flow-independent measure of orifice area, but it may also be influenced by atrial and ventricular factors. Pressure half time and peak left ventricular inflow velocity were measured by continuous wave Doppler ultrasound in 164 patients with normally functioning Carpentier-Edwards, Björk-Shiley, and Starr-Edwards mitral prostheses. Pressure half time was shorter in the Björk-Shiley than in the other value types and peak transmitral velocity was highest in the Starr-Edwards prostheses. These differences, however, were partly explained by coexistent differences in transmitral flow. Filling time accounted for 19% and stroke volume for 15% of the variance in pressure half time compared with only 5.6% for prosthetic design and 0.4% for annulus diameter when each of these variables was considered alone. The design of the prosthesis explained 18% of the variance in peak transmitral velocity, while cardiac output and annulus diameter did not contribute significantly. With Doppler ultrasound it is impossible to define reliable normal ranges for prosthetic function independently of atrial and ventricular function. Formulas for orifice area based on peak transmitral velocity and flow seem more likely to reflect the behaviour of normally functioning prostheses than those based on pressure half time.

Entities:  

Mesh:

Year:  1990        PMID: 2183860      PMCID: PMC1024405          DOI: 10.1136/hrt.63.3.189

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  33 in total

1.  The Gorlin formula validated against directly observed orifice area in porcine mitral bioprostheses.

Authors:  J B Chambers; T Cochrane; M M Black; G Jackson
Journal:  J Am Coll Cardiol       Date:  1989-02       Impact factor: 24.094

2.  The effect of flow on Doppler estimates of bioprosthetic mitral valve function in vitro.

Authors:  J B Chambers; T Cochrane; M M Black; G Jackson
Journal:  Cardiovasc Res       Date:  1989-12       Impact factor: 10.787

3.  Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Authors:  I P Panidis; J Ross; G S Mintz
Journal:  J Am Coll Cardiol       Date:  1986-08       Impact factor: 24.094

4.  Color Doppler assessment of mitral regurgitation with orthogonal planes.

Authors:  F Helmcke; N C Nanda; M C Hsiung; B Soto; C K Adey; R G Goyal; R P Gatewood
Journal:  Circulation       Date:  1987-01       Impact factor: 29.690

5.  Left ventricular volume and mass from single-plane cineangiocardiogram. A comparison of anteroposterior and right anterior oblique methods.

Authors:  J W Kennedy; S E Trenholme; I S Kasser
Journal:  Am Heart J       Date:  1970-09       Impact factor: 4.749

Review 6.  Doppler mitral pressure half-time: a clinical tool in search of theoretical justification.

Authors:  J D Thomas; A E Weyman
Journal:  J Am Coll Cardiol       Date:  1987-10       Impact factor: 24.094

Review 7.  Diastolic properties of the left ventricle.

Authors:  W Grossman; L P McLaurin
Journal:  Ann Intern Med       Date:  1976-03       Impact factor: 25.391

8.  Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves.

Authors:  G A Williams; A J Labovitz
Journal:  Am J Cardiol       Date:  1985-08-01       Impact factor: 2.778

9.  In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates.

Authors:  S Gabbay; D M McQueen; E L Yellin; R M Becker; R W Frater
Journal:  J Thorac Cardiovasc Surg       Date:  1978-12       Impact factor: 5.209

10.  Doppler echocardiographic evaluation of patients with porcine mitral valves.

Authors:  T Ryan; W F Armstrong; J C Dillon; H Feigenbaum
Journal:  Am Heart J       Date:  1986-02       Impact factor: 4.749

View more
  1 in total

1.  Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.

Authors:  P Weiss; A Hoffmann; D Burckhardt
Journal:  Br Heart J       Date:  1992-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.