Literature DB >> 21587215

Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Jesse Habets1, Ricardo P Budde, Petr Symersky, Renee B van den Brink, Bas A de Mol, Willem P Mali, Lex A van Herwerden, Steven A Chamuleau.   

Abstract

Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these techniques sometimes fail to determine the specific cause of PHV dysfunction, which is crucial to the selection of the appropriate treatment strategy. Multidetector-row CT (MDCT) can be of additional value in diagnosing the specific cause of PHV dysfunction and provides valuable complimentary information for surgical planning in case of reoperation. Cardiac magnetic resonance imaging (CMR) has limited value in the evaluation of biological PHV dysfunction. In this Review, we discuss the use of established imaging modalities for the detection of left-sided mechanical and biological PHV dysfunction and discuss the complementary role of MDCT in this context.

Entities:  

Mesh:

Year:  2011        PMID: 21587215     DOI: 10.1038/nrcardio.2011.71

Source DB:  PubMed          Journal:  Nat Rev Cardiol        ISSN: 1759-5002            Impact factor:   32.419


  152 in total

1.  Complicated ruptured sinus of Valsalva: cardiac computed tomographic angiography (64 slice) predicts surgical appearance and obviates need for invasive cardiac catheterization.

Authors:  Thomas K Ro; Bruno R Cotter; Sinan A Simsir; Ronald P Karlsberg
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-08-31

2.  Images in cardiovascular medicine. Cardiac CT assessment of prosthetic aortic valve dysfunction secondary to acute thrombosis and response to thrombolysis.

Authors:  Jonathan Chan; Mohamed Marwan; Taziano Schepis; Dieter Ropers; Leanne Du; Stephan Achenbach
Journal:  Circulation       Date:  2009-11-10       Impact factor: 29.690

3.  The influence of the design on the medium to long-term hemodynamic behavior of 19 mm pericardial aortic valve prostheses.

Authors:  J R Gonzalez-Juanatey; J B Garcia-Bengoechea; J M Garcia-Acuna; M Vega Fernandez; A Amaro Cendon; A Varela Roman; M Gil de la Pena
Journal:  J Heart Valve Dis       Date:  1996-11

4.  Postoperative hemodynamics of two bileaflet heart valves in the aortic position.

Authors:  W Flameng; A Vandeplas; K Narine; W Daenen; P Herijgers; M C Herregods
Journal:  J Heart Valve Dis       Date:  1997-05

5.  Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Authors:  I P Panidis; J Ross; G S Mintz
Journal:  J Am Coll Cardiol       Date:  1986-08       Impact factor: 24.094

6.  Improved Doppler assessment of the Bjork-Shiley mitral prosthesis using the continuity equation.

Authors:  J C Mohan; R Agrawal; R Arora; M Khalilullah
Journal:  Int J Cardiol       Date:  1994-03-01       Impact factor: 4.164

7.  Prosthesis-patient mismatch: hemodynamic comparison of stented and stentless aortic valves.

Authors:  K L Yun; W R Jamieson; S Khonsari; L H Burr; A I Munro; C F Sintek
Journal:  Semin Thorac Cardiovasc Surg       Date:  1999-10

8.  Hemodynamic comparison of second- and third-generation stented bioprostheses in aortic valve replacement.

Authors:  W R Jamieson; M T Janusz; J MacNab; C Henderson
Journal:  Ann Thorac Surg       Date:  2001-05       Impact factor: 4.330

Review 9.  Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement?

Authors:  Stefano Urso; Rafael Sadaba; Gonzalo Aldamiz-Echevarria
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-06-04

Review 10.  Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.

Authors:  S C Cannegieter; F R Rosendaal; E Briët
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

View more
  22 in total

1.  Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients.

Authors:  Wei-Guo Ma; Bin Hou; Adiljan Abdurusul; Ding-Xu Gong; Yue Tang; Qian Chang; Jian-Ping Xu; Han-Song Sun
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  Assessment of a transcatheter heart valve prosthesis with multidetector computed tomography: in vitro and in vivo imaging characteristics.

Authors:  Linda M de Heer; Jesse Habets; Jolanda Kluin; Pieter R Stella; Willem P Th M Mali; Lex A van Herwerden; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-09       Impact factor: 2.357

3.  Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.

Authors:  Young Joo Suh; Young Jin Kim; Sak Lee; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Byoung Wook Choi; Byung-Chul Chang
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-21       Impact factor: 2.357

4.  The impact of a new model-based iterative reconstruction algorithm on prosthetic heart valve related artifacts at reduced radiation dose MDCT.

Authors:  Dominika Suchá; Martin J Willemink; Pim A de Jong; Arnold M R Schilham; Tim Leiner; Petr Symersky; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-29       Impact factor: 2.357

5.  A mass obstructing mechanical prosthetic heart valve: thrombus or pannus?

Authors:  Kunal Mahajan; Sanjeev Asotra; Prakash Negi; Prince Kumar Paul
Journal:  BMJ Case Rep       Date:  2017-07-13

6.  Echocardiographic assessment of prosthetic valves.

Authors:  Kazuaki Tanabe
Journal:  J Echocardiogr       Date:  2015-08-19

7.  Cardiac computed tomography angiography results in diagnostic and therapeutic change in prosthetic heart valve endocarditis.

Authors:  Jesse Habets; Wilco Tanis; Lex A van Herwerden; Renee B A van den Brink; Willem P Th M Mali; Bas A J M de Mol; Steven A J Chamuleau; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-30       Impact factor: 2.357

Review 8.  Mechanical valve obstruction: Review of diagnostic and treatment strategies.

Authors:  Jason Salamon; Jerson Munoz-Mendoza; Jared J Liebelt; Cynthia C Taub
Journal:  World J Cardiol       Date:  2015-12-26

9.  CT attenuation measurements are valuable to discriminate pledgets used in prosthetic heart valve implantation from paravalvular leakage.

Authors:  J Habets; T S Meijer; R C A Meijer; W P Th M Mali; E-J P A Vonken; R P J Budde
Journal:  Br J Radiol       Date:  2012-09       Impact factor: 3.039

10.  [Imaging following valve replacement].

Authors:  D Dabir; E Arroyo-Ucar; E A Ucar; E Nagel
Journal:  Radiologe       Date:  2013-10       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.