Literature DB >> 2757868

Colour flow Doppler mapping in the assessment of prosthetic valve regurgitation.

J Chambers1, M Monaghan, G Jackson.   

Abstract

Two hundred Carpentier-Edwards, Björk-Shiley, and Starr-Edwards prostheses in 173 patients were examined. Sixteen (16%) in the aortic and 24 (25%) in the mitral position were associated with clinical signs of regurgitation. A phased array system (Hewlett-Packard A77020A) with a 2.5 MHz duplex and 1.9 MHz continuous wave transducer was used. Colour flow mapping showed trivial transvalvar regurgitation in 23 (53%) metal aortic prosthesis, and only nine (20%) metal mitral prostheses. This difference was probably attributable to shielding of the left atrium by the metal components. Colour mapping confirmed abnormal regurgitation in all aortic prostheses with early diastolic numbers, but regurgitation was also shown in 25 (29%) with no diastolic murmur. Abnormal mitral regurgitation was found in 13 (54%) patients with a pansystolic murmur, but also in six (8%) with no systolic murmur. Two patients, thought on clinical grounds to have mild mitral regurgitation, had unexpectedly large jets on colour flow mapping. About one in three prostheses had paraprosthetic leaks, 65 (79%) of which were small with a jet area less than 20% of the area of the receiving chamber. The development of new paraprosthetic leaks led to the diagnosis of bacterial endocarditis in two patients. In eight patients regurgitation was first diagnosed with continuous wave Doppler, but was afterwards shown with colour mapping and in a further 10 regurgitation could only be shown by continuous wave Doppler. Colour flow mapping was less sensitive than continuous wave Doppler in detecting regurgitation,but seemed able to distinguish normal transvalvar from paraprosthetic regurgitation. Further studies in the natural course of paraprosthetic leaks and a comparison of the transoesophageal and transthoracic approaches in the assessment of mitral prostheses are needed.

Entities:  

Mesh:

Year:  1989        PMID: 2757868      PMCID: PMC1216722          DOI: 10.1136/hrt.62.1.1

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  13 in total

1.  Doppler evaluation of bioprosthetic and mechanical aortic valves: data from four models in 107 stable, ambulatory patients.

Authors:  M L Ramirez; M Wong; N Sadler; P M Shah
Journal:  Am Heart J       Date:  1988-02       Impact factor: 4.749

2.  Color Doppler assessment of mitral regurgitation with orthogonal planes.

Authors:  F Helmcke; N C Nanda; M C Hsiung; B Soto; C K Adey; R G Goyal; R P Gatewood
Journal:  Circulation       Date:  1987-01       Impact factor: 29.690

3.  Doppler echocardiographic characteristics of the Carpentier-Edwards xenograft.

Authors:  J L Gibbs; G A Wharton; G J Williams
Journal:  Eur Heart J       Date:  1986-04       Impact factor: 29.983

4.  Doppler echocardiographic appearance of cusp tears in tissue valve prosthesis.

Authors:  J B Chambers; M J Monaghan; G Jackson; D E Jewitt
Journal:  J Am Coll Cardiol       Date:  1987-08       Impact factor: 24.094

5.  Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.

Authors:  C Veyrat; S Witchitz; A Lessana; A Ameur; G Abitbol; D Kalmanson
Journal:  Br Heart J       Date:  1985-09

6.  Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values.

Authors:  K B Sagar; L S Wann; W H Paulsen; D W Romhilt
Journal:  J Am Coll Cardiol       Date:  1986-03       Impact factor: 24.094

7.  Doppler color flow mapping.

Authors:  D F Switzer; N C Nanda
Journal:  Ultrasound Med Biol       Date:  1985 May-Jun       Impact factor: 2.998

8.  Color Doppler echocardiographic assessment of the change in the mitral regurgitant volume.

Authors:  Y Otsuji; C Tei; A Kisanuki; K Natsugoe; Y Kawazoe
Journal:  Am Heart J       Date:  1987-08       Impact factor: 4.749

9.  Semiquantitative grading of severity of mitral regurgitation by real-time two-dimensional Doppler flow imaging technique.

Authors:  K Miyatake; S Izumi; M Okamoto; N Kinoshita; H Asonuma; H Nakagawa; K Yamamoto; M Takamiya; H Sakakibara; Y Nimura
Journal:  J Am Coll Cardiol       Date:  1986-01       Impact factor: 24.094

10.  The development of real-time two-dimensional Doppler echocardiography and its clinical significance in acquired valvular diseases. With special reference to the evaluation of valvular regurgitation.

Authors:  R Omoto; Y Yokote; S Takamoto; S Kyo; K Ueda; H Asano; K Namekawa; C Kasai; Y Kondo; A Koyano
Journal:  Jpn Heart J       Date:  1984-05
View more
  3 in total

1.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

2.  Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves).

Authors:  Rebecca T Hahn; Philippe Pibarot; William J Stewart; Neil J Weissman; Deepika Gopalakrishnan; Martin G Keane; Saif Anwaruddin; Zuyue Wang; Martin Bilsker; Brian R Lindman; Howard C Herrmann; Susheel K Kodali; Raj Makkar; Vinod H Thourani; Lars G Svensson; Jodi J Akin; William N Anderson; Martin B Leon; Pamela S Douglas
Journal:  J Am Coll Cardiol       Date:  2013-04-23       Impact factor: 24.094

3.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography.

Authors:  A Ionescu; A G Fraser; E G Butchart
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

  3 in total