| Literature DB >> 35681163 |
Hossam I Nassar1, Medhat Sameh Abdelaziz2.
Abstract
OBJECTIVES: The aim of the present study was to evaluate the retention and loss of retention after fatigue testing at different time intervals between two types of bar clip materials (digitally designed PEEK bar clip and regular Nylon bar clip).Entities:
Keywords: Computer-aided design; Dental implantation; Dental materials; Denture precision attachment; Denture retention
Mesh:
Substances:
Year: 2022 PMID: 35681163 PMCID: PMC9178882 DOI: 10.1186/s12903-022-02262-7
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 3.747
Fig. 1Bar fabricated over the model
Fig. 2Outlining the PEEK clip
Fig. 3The final for PEEK clip design with an outer surface undercut to provide mechanical retention with the denture
Fig. 4Pressed PEEK clip
Fig. 5Two nylon clips over the bar for pick up
Fig. 6Two PEEK clips over the bar for pick up
Fig. 7Pick up of the nylon clip in the denture
Fig. 8Pick up of the PEEK clip in the denture
Fig. 9Bar chart of mean retention loss in (Newton) between the two studied groups at a different time of measurement primary retention versus one, two, and three years of use
Retention in (Newton) between the two studied groups at various measurement times
| PEEK clip | Nylon clip | ||
|---|---|---|---|
| T0 | 42.08 ± 1.52 | 16.08 ± 0.68 | 0.000* |
| T1 | 19.26 ± 1.15 | 15.78 ± 0.93 | 0.000* |
| T2 | 19.90 ± 0.73 | 15.22 ± 0.53 | 0.000* |
| T3 | 17.37 ± 1.07 | 16.56 ± 0.88 | 0.055 NS |
T0, at time of overdenture insertion; T1, after 1 year of use; T2, after 2 years of use; T3, after 3 years of use; NS, Statistically not significant (p ≥ 0.05)
Repeated measure analysis of variance, comparing retention loss in (Newton) between different time periods of measurement (Primary retention vs one, two, and three years of use) in each studied group
| PEEK clip | Nylon clip | |
|---|---|---|
| T0–T1 | 0.000* | 1.000 NS |
| T0–T2 | 0.000* | 0.002* |
| T0–T3 | 0.000* | 0.195 NS |
| T1–T2 | 1.000 NS | 0.420 NS |
| T1–T3 | 0.000* | 0.006* |
| T2–T3 | 0.001* | 0.000* |
T0, at time of overdenture insertion; T1, after 1 year of use; T2, after 2 years of use; T3, after 3 years of use; NS, Statistically not significant (p ≥ 0.05)
*Statistically significant (p < 0.05)
Percentage of retention loss in (Newton) between the two studied groups at various times of measurement Primary retention vs one, two, and three years of use
| PEEK clip | Nylon clip | p value | |
|---|---|---|---|
| Percentage change | |||
| T1 versus T0 (%) | − 54.13 | − 1.80 | 0.000* |
| T2 versus T0 (%) | − 52.63 | − 5.24 | 0.000* |
| T2 versus T1 (%) | + 3.72 | − 3.28 | 0.018* |
| T3 versus T0 (%) | − 58.66 | + 2.99 | 0.000* |
| T3 versus T2 (%) | − 12.53 | + 8.76 | 0.000* |
T0, at time of overdenture insertion; T1, after 1 year of use; T2, after 2 years of use; T3, after 3 years of use; NS, Statistically not significant (p ≥ 0.05)
*Statistically significant (p < 0.05)