Literature DB >> 17207077

Influence of attachment wear on retention of mandibular overdenture.

V Rutkunas1, H Mizutani, H Takahashi.   

Abstract

UNLABELLED: The aims of this study were: (i) to evaluate and compare retention of two-teeth (implant) supported mandibular overdenture with either stud or magnetic attachments during linear (axial) and rotational (paraxial) dislodgements; (ii) to compare retentive properties before and after wear simulation. The test group consisted of five magnetic and four stud overdenture attachments (n = 12 specimens for each attachment type). Retention in axial direction was evaluated on one-tooth (implant) model by measuring maximum retentive force (N) and range of retention (mm) during the linear dislodgement. Retention in the paraxial direction was evaluated on mandibular-overdenture model by measuring the maximum retentive force (N) during three types of rotational dislodgements - anterior, lateral and posterior. The minimum number of cycles required to simulate wear was determined by special wear test. Afterwards, the wear was simulated in the test group, and retention in axial and paraxial directions was measured again. STATISTICAL ANALYSIS: one-way anova, Scheffe post hoc and paired-samples t-tests (P < 0.05). Initially, studs had higher retention (4-11 N) than magnets (4.5-6 N) in axial direction. After the wear simulation, it had decreased from 76% to 48% for some of the studs and had become similar to the retention of magnetic attachments. Magnets had lower retention range (0.2-0.3 mm) than studs (0.5-1.1 mm). Studs provided similar or higher retention in paraxial directions than magnetic attachments both before and after wear simulation. Retentive properties of magnets decreased mostly with posterior rotational dislodgement. Retentive properties of stud overdenture attachments were less constant.

Entities:  

Mesh:

Year:  2007        PMID: 17207077     DOI: 10.1111/j.1365-2842.2006.01640.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  16 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Tooth Supported Overdenture Retained with Custom Attachments: A Case Report.

Authors:  Siddharth Bansal; Meena A Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2013-12-12

3.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

4.  Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.

Authors:  Nobuhiro Yoda; Yoshiki Matsudate; Masaru Abue; Guang Hong; Keiichi Sasaki
Journal:  J Dent Biomech       Date:  2015-03-16

Review 5.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

6.  The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.

Authors:  Farhad Tabatabaian; Abolfazl Saboury; Zahra Sadat Sobhani; Vicki C Petropoulos
Journal:  J Dent (Tehran)       Date:  2014-09-30

7.  Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Elena Martin-Fernandez; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

8.  Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study.

Authors:  Nesma El-Amier; Ehab Elsaih; Mona Gibreel; Hassan El-Motaiam
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

Review 9.  Telescopic Denture.

Authors:  Mohammad Ayham Hakkoum; Ghassan Wazir
Journal:  Open Dent J       Date:  2018-03-30

10.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.