Testing the retention of attachments for implant overdentures - validation of an original force measurement system.

O Fromentin1, C Lassauzay, S Abi Nader, J Feine, R F de Albuquerque Junior.   

Abstract

The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Mesh:

Substances:

Year:  2009        PMID: 19912482     DOI: 10.1111/j.1365-2842.2009.02020.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  11 in total

1.  Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading.

Authors:  Mateus Bertolini Fernandes Dos Santos; Bruno Massucato Zen; Atais Bacchi
Journal:  Med Biol Eng Comput       Date:  2015-12-11       Impact factor: 2.602

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study.

Authors:  Parsa Atashrazm; Mohammad Hossein Dashti; Leila Zamani Alavijeh; Samira Azarmaeh; Sayena Mahdizadeh
Journal:  J Indian Prosthodont Soc       Date:  2013-04-12

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

6.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

7.  Measuring the retention of removable mandibular prostheses by a standardized model: A technical report.

Authors:  Khaing Myat Thu; Haruki Shimizu; Manabu Kanazawa; Shunsuke Minakuchi
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

8.  Performance of attachments used in implant-supported overdentures: review of trends in the literature.

Authors:  Damian J Lee
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

9.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01

10.  Effect of bar cross-section and female housing material on retention of mandibular implant bar overdentures: A comparative in vitro study.

Authors:  Elsayed A Abdel-Khalek; Abdullah M Ibrahim
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.